YASKAWA GA700 Technical Manual page 696

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.6 E: Motor Parameters
E1-05: Maximum Output Voltage
No.
Name
(Hex.)
E1-05
Maximum Output
Voltage
(0304)
E1-06: Base Frequency
No.
Name
(Hex.)
E1-06
Base Frequency
(0305)
E1-07: Mid Point A Frequency
No.
Name
(Hex.)
E1-07
Mid Point A
Frequency
(0306)
E1-08: Mid Point A Voltage
No.
Name
(Hex.)
E1-08
Mid Point A Voltage
(0307)
Note:
Default setting is determined by A1-02 [Control Method Selection], C6-01 [Normal / Heavy Duty Selection], and o2-04 [Drive Model
Selection].
E1-09: Minimum Output Frequency
No.
Name
(Hex.)
E1-09
Minimum Output
Frequency
(0308)
E1-10: Minimum Output Voltage
No.
Name
(Hex.)
E1-10
Minimum Output
Voltage
(0309)
E1-11: Mid Point B Frequency
No.
Name
(Hex.)
E1-11
Mid Point B
Frequency
(030A)
696
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the middle output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the middle output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the mid point B frequency.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
Determined by A1-02
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Default Setting
(Range)
Determined by A1-02
and E5-01
(0.0 to E1-04)
Default Setting
(Range)
Determined by A1-02
(0.0 to E-04)
Default Setting
(Range)
Determined by A1-02
(200 V Class: 0.0 to
255.0 V,
400 V Class: 0.0 to
510.0 V)
Default Setting
(Range)
Determined by A1-02
and E5-01
(Determined by A1-
02, E1-04, and E5-
01)
Default Setting
(Range)
Determined by A1-02
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Default Setting
(Range)
0.0 Hz
(0.0 to E-04)