YASKAWA GA700 Technical Manual page 460

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.10 H: Terminal Functions
Setting
Function
7
Overtorque/
Undertorque
DetectLvl
8
Stall Prevention
Level DuringRun
9
Output Freq Lower
Limit Level
B
PID Feedback
C
PID Setpoint
D
Frequency Bias
E
Motor Temperature
(PTC input)
F
Through Mode
10
Forward Torque
Limit
11
Reverse Torque
Limit
12
Regenerative
Torque Limit
13
Torque Reference /
Torque Limit
14
Torque
Compensation
15
General Torque
Limit
16
Differential PID
Feedback
1F
Through Mode
30
DriveWorksEZ
analog input 1
31
DriveWorksEZ
analog input 2
32
DriveWorksEZ
analog input 3
460
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the signal that adjusts the overtorque/undertorque detection level.
Note:
Use this function in conjunction with L6-01 [Torque Detection Selection 1]. This
parameter functions in place of L6-02 [Torque Detection Level 1].
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the signal that adjusts the stall prevention level during run assuming that the drive
rated current is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the signal that adjusts the output frequency lower limit level assuming that E1-04
[Maximum Output Frequency] is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the PID feedback value.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the PID setpoint.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the bias value added to the frequency reference assuming that E1-04 [Maximum
Output Frequency] is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Uses the motor Positive Temperature Coefficient (PLC) thermistor to protect the motor
from heat on the basis that the current value at the time the 10 V (or 20 mA) analog
signal is input is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting when terminals are not used or to use terminals in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the forward torque limit assuming that the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the load torque limit assuming that the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the regenerative torque limit assuming that the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the torque reference assuming that the motor rated torque is 100%. This parameter
operates as the torque limit for speed control.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the torque compensation value assuming that the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the torque limit common to all quadrants for forward, reverse, and regenerative
operation assuming that the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the PID differential feedback value assuming that the full scale analog signal (10
V or 20 mA) is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting when terminals are not used or to use terminals in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Used with DriveWorksEZ. Refer to the DriveWorksEZ Online Manual for more
information.
V/f
CL-V/f
OLV
CLV
AOLV
Used with DriveWorksEZ. Refer to the DriveWorksEZ Online Manual for more
information.
V/f
CL-V/f
OLV
CLV
AOLV
Used with DriveWorksEZ. Refer to the DriveWorksEZ Online Manual for more
information.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Ref.
809
809
809
809
810
810
810
810
810
811
812
812
812
812
812
812
812
812
813