A.16 Control Mode Dependent Parameter Default Values
The tables below list parameters that depend on the control mode selection. Changing the control mode initializes these
parameters to the values shown here.
u
A1-02 (Control Mode) Dependent Parameters
No.
b1-24
Commercial Power Switching Selection
b2-01
DC Injection Braking Start Frequency
b2-04
DC Injection Braking Time at Stop
Current Control Gain during Speed Search
b3-08
(Speed Estimation Type)
Current Control Integral Time during Speed Search
b3-09
(Speed Estimation Type)
b3-24
Speed Search Method Selection
b8-01
Energy Saving Control Selection
C2-01
S-Curve Time at Acceleration Start
C4-01
Torque Compensation Gain
C4-02
Torque Compensation Primary Delay Time
C6-02
Carrier Frequency Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-07
Middle Output Frequency
E1-08
Middle Output Frequency Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Frequency Voltage
L1-01
Motor Overload Protection Selection
L8-18
Software Current Limit Selection
L8-38
Carrier Frequency Reduction Selection
L8-40
Carrier Frequency Reduction Off Delay Time
<1> Default setting value is determined by parameter o2-04, Drive Model Selection.
<2> Default setting is dependent on parameter E5-01, Motor Code Selection.
<3> Values shown are specific to 200 V class drives. Double the values for 400 V class drives.
<4> This setting value depends on rated output current and V/f pattern selection in parameter E1-03.
<5> Default setting value is determined by the drive software version.
PRG: 6113 and earlier: 0
PRG: 6114 and later: Default setting is dependent on parameter A1-02, Control Method Selection
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
Table A.3 A1-02 (Control Mode) Dependent Parameters and Default Values
Name
A.16 Control Mode Dependent Parameter Default Values
Setting Range
Resolution
0, 1
0.0 to 10.0
0.1 Hz
0.00 to 10.00
0.00 to 6.00
0.0 to 1000.0
0.0 ms
1, 2
0, 1
0.00 to 10.00
0.00 to 2.50
0 to 10000
1 to 4, F
40.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0.0 to 400.0
0.1 Hz
0.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0 to 4
0 to 1
0 to 2
0.00 to 2.00
Control Modes (A1-02)
V/f (0)
–
0
0.5 Hz
0.01 s
0.50 s
<1>
–
2.00 ms
–
2
–
0
0.01 s
0.20 s
0.01
1.00
1 ms
200 ms
<1>
–
60.0
<4>
0.1 V
575
60.0
3.0
<4>
0.1 V
15.0
1.5
0.1 V
9.0
–
1
<5>
–
<1>
–
0.01 s
0.50 s
OLV/PM (5)
0
0.5 Hz
0.00 s
0.3
4.00 ms
2
–
1.00 s
0.00
100 ms
<1>
<2>
<2>
<2>
–
–
<2>
–
4
0
0
0.00 s
A
257