Control Mode Dependent Parameter Default Values; Control Mode Dependent Parameter Default Values; A1-02 (Control Mode) Dependent Parameters - YASKAWA Z1000U Series Programming Manual

Hvac matrix low harmonic drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

A.16 Control Mode Dependent Parameter Default Values
The tables below list parameters that depend on the control mode selection. Changing the control mode initializes these
parameters to the values shown here.
u

A1-02 (Control Mode) Dependent Parameters

No.
b1-24
Commercial Power Switching Selection
b2-01
DC Injection Braking Start Frequency
b2-04
DC Injection Braking Time at Stop
Current Control Gain during Speed Search
b3-08
(Speed Estimation Type)
Current Control Integral Time during Speed Search
b3-09
(Speed Estimation Type)
b3-24
Speed Search Method Selection
b8-01
Energy Saving Control Selection
C2-01
S-Curve Time at Acceleration Start
C4-01
Torque Compensation Gain
C4-02
Torque Compensation Primary Delay Time
C6-02
Carrier Frequency Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-07
Middle Output Frequency
E1-08
Middle Output Frequency Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Frequency Voltage
L1-01
Motor Overload Protection Selection
L8-18
Software Current Limit Selection
L8-38
Carrier Frequency Reduction Selection
L8-40
Carrier Frequency Reduction Off Delay Time
<1> Default setting value is determined by parameter o2-04, Drive Model Selection.
<2> Default setting is dependent on parameter E5-01, Motor Code Selection.
<3> Values shown are specific to 200 V class drives. Double the values for 400 V class drives.
<4> This setting value depends on rated output current and V/f pattern selection in parameter E1-03.
<5> Default setting value is determined by the drive software version.
PRG: 6113 and earlier: 0
PRG: 6114 and later: Default setting is dependent on parameter A1-02, Control Method Selection
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
Table A.3 A1-02 (Control Mode) Dependent Parameters and Default Values
Name
A.16 Control Mode Dependent Parameter Default Values
Setting Range
Resolution
0, 1
0.0 to 10.0
0.1 Hz
0.00 to 10.00
0.00 to 6.00
0.0 to 1000.0
0.0 ms
1, 2
0, 1
0.00 to 10.00
0.00 to 2.50
0 to 10000
1 to 4, F
40.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0.0 to 400.0
0.1 Hz
0.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0.0 to 400.0
0.1 Hz
<3>
0.0 to 255.0
0 to 4
0 to 1
0 to 2
0.00 to 2.00
Control Modes (A1-02)
V/f (0)
0
0.5 Hz
0.01 s
0.50 s
<1>
2.00 ms
2
0
0.01 s
0.20 s
0.01
1.00
1 ms
200 ms
<1>
60.0
<4>
0.1 V
575
60.0
3.0
<4>
0.1 V
15.0
1.5
0.1 V
9.0
1
<5>
<1>
0.01 s
0.50 s
OLV/PM (5)
0
0.5 Hz
0.00 s
0.3
4.00 ms
2
1.00 s
0.00
100 ms
<1>
<2>
<2>
<2>
<2>
4
0
0
0.00 s
A
257