YASKAWA GA700 Technical Manual page 921

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

T2-11: PM Motor d-Axis Inductance
No.
Name
(Hex.)
T2-11
PM Motor d-Axis
Inductance
(0735)
T2-12: PM Motor q-Axis Inductance
No.
Name
(Hex.)
T2-12
PM Motor q-Axis
Inductance
(0736)
T2-13: InducedVoltage Const Unit Select
No.
Name
(Hex.)
T2-13
InducedVoltage
Const Unit Select
(0755)
0 : mV/min
-1
1 : mV/(rad/s)
Note:
• If T2-13 = 0 is set, then the drive will use E5-24 [PM Back-EMF L-L Vrms (mV/rpm)], and will automatically set E5-09 [PM Back-
EMF Vpeak (mV/(rad/s))] to 0.0.
• If T2-13 = 1 is set, then the drive will useE5-09 and will automatically set E5-24 to 0.0.
T2-14: PM Motor Induced Voltage Const
No.
Name
(Hex.)
T2-14
PM Motor Induced
Voltage Const
(0737)
T2-15: Pull-InCurrentLv forPM Motor Tun
No.
Name
(Hex.)
T2-15
Pull-InCurrentLv
forPM Motor Tun
(0756)
Increase the setting value if the load inertia is significant.
T2-16: PGNumOfPulses/Rev forPMMotor Tun
No.
Name
(Hex.)
T2-16
PGNumOfPulses/Rev
forPMMotor Tun
(0738)
Set the actual number of pulses for one full motor rotation.
T2-17: Encoder Z-Pulse Offset
No.
Name
(Hex.)
T2-17
Encoder Z-Pulse
Offset
(0757)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-Axis inductance of the motor on a per phase basis.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the q-Axis inductance of the motor on a per phase basis.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the unit used for setting the induced voltage constant.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor induced voltage constant (Ke).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level of the pull-in current as a percentage, with 100% representing
the motor rated current. Normally there is no need to configure this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PG (pulse generator, encoder) pulses.
V/f
CL-V/f
OLV
CLV
AOLV
If the encoder Z-pulse offset (Δθ) (pulse generator, encoder) is listed on the
motor nameplate, set it in units of 0.1°.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.12 T: Auto-Tuning
Default Setting
(Range)
Determined by T2-02
(0.00 - 600.00 mH)
Default Setting
(Range)
Determined by T2-02
(0.00 - 600.00 mH)
Default Setting
(Range)
1
(0, 1)
Default Setting
(Range)
Determined by T2-13
(0.0 - 2000.0)
Default Setting
(Range)
30%
(0 - 120%)
Default Setting
(Range)
1024 ppr
(1 - 15000 ppr)
Default Setting
(Range)
0.0°
(-180.0 - +180.0°)
921