11.7 F: Options
F1-20: Encoder 1 PCB Disconnect Detect
No.
Name
(Hex.)
F1-20
PG Option PCB
Disconnect Detect1
(03B4)
0 : Disabled
1 : Enabled
F1-21: Encoder 1 Signal Selection
No.
Name
(Hex.)
F1-21
PG 1 Signal Selection
(03BC)
0 : A pulse detection
1 : AB pulse detection
F1-30: Motor 2 Encoder PCB Port Select
No.
Name
(Hex.)
F1-30
Motor 2 PG Option
Port Selection
(03AA)
0 : CN5-C
Selects when the speed feedback from the encoder for motor 1 and motor 2 is received by one option card while
such signals are switched externally.
1 : CN5-B
Selects when the speed feedback from the encoder for motor 1 and motor 2 is received by two encoder option
cards independently.
F1-31: Encoder 2 Pulse Count (PPR)
No.
Name
(Hex.)
F1-31
PG 2 Pulses Per
Revolution
(03B0)
F1-32: Encoder 2 Rotation Selection
No.
Name
(Hex.)
F1-32
PG 2 Rotation
Selection
(03B1)
Refer to the installation manual included with the option card for more information on how to confirm and set the
encoder pulse output sequence.
0 : Pulse A leads
1 : Pulse B leads
716
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to enable or disable the disconnection detection function for
the encoder connection cable regarding the PG-X3 and PG-F3. Detects
PGoH [PG Hardware Fault] when F1-20 = 1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the type of pulse signal (channel) used for the encoder option card.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the connector used when the motor 2 encoder option card is
mounted in the drive.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of output pulses per revolution of the encoder. This
parameter is for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the output sequence for phases A and B of the pulses output from
the encoder, given that the motor is running forward. This parameter is for
motor 2.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
1
(0, 1)
Default Setting
(Range)
0
(0, 1)
Default Setting
(Range)
1
(0, 1)
Default Setting
(Range)
600 ppr
(1 - 60000 ppr)
Default Setting
(Range)
0
(0, 1)

Advertisement