YASKAWA GA700 Technical Manual page 407

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
b5-40
Frequency
Reference Monitor
(017F)
@PID
b5-47
PID Output
Reverse Selection
(017D)
2
b5-53
Integrator Ramp
Limit
(0B8F)
RUN
b5-54
PID softstarter
cancel selection
(0BB7)
b5-55
PID feedback
monitor selection
(0BE1)
b5-56
PID feedback
monitor gain
(0BE2)
b5-57
PID Feedback
Monitor Bias
(11DD)
b5-58
PID Setpoints 2
through b5-
through 4
60
(1182 -
1184)
RUN
b5-61
PID Trim lower
limit selection
(119A)
b5-62
PID Trim lower
limit
(119B)
b5-63
Differential PID
Feedback Select
(119C)
b5-64
Differential PID
Feedback Gain
(119D)
b5-65
PID Diff Fdbk
Monitor Bias
(119F)
b5-66
PID feedback
monitor Lvl
(11DE)
b5-67
PID Diff Fdbk
monitor Lvl
(11DF)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Selects the contents displayed in monitor U1-01 [Freq Reference]
when using PID control.
0 : with PID
1 : without PID
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether or not the motor should rotate in reverse when the PID
control output is negative.
0 : Disabled: 0 lower limit
1 : Enabled: Negative lower limit
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the responsiveness of PID control when the PID feedback
changes rapidly.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the relationship between the soft starter and PID input/
output.
0 : None
1 : Softstarter is canceled
V/f
CL-V/f
OLV
CLV
AOLV
Selects the monitor (Ux-xx) used as the PID Feedback.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the gain for the monitor selected with b5-55 [PID
feedback monitor selection].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the bias for the monitor selected with b5-55 [PID
feedback monitor selection].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the PID setpoint selected with H1-xx = 3E or 3F
[Terminal Sx Function Select = PID Setpoint Selection 1/2]. This
parameter is configured on the basis of the maximum output
frequency being the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the function used to adjust the PID output in proportion
with the frequency reference.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Configures the lower limit of the PID frequency reference trim on
the basis of the maximum output frequency as the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the monitor (Ux-xx) used as the PID Differential Feedback.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the gain of the monitor configured with b5-63
[Differential PID Feedback Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the bias for the monitor selected with b5-63 [Differential
PID Feedback Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the signal level for the monitor selected with b5-55 [PID
feedback monitor selection].
0 : Absolute
1 : +-
V/f
CL-V/f
OLV
CLV
AOLV
Configures the signal level for the monitor selected with b5-63
[Differential PID Feedback Select].
0 : Absolute
1 : +-
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.5 b: Application
Default
Ref.
(Range)
0
629
(0, 1)
1
630
(0, 1)
0.0 Hz
630
(0.0 - 10.0 Hz)
0
630
(0, 1)
000
630
(000 - 999)
1.00
631
(0.00 - 10.00)
0.00
631
(-10.00 - +10.00)
0.00%
631
(0.00 - 100.00%)
0
631
(0, 1)
0.00%
632
(0.00 - 100.00%)
000
632
(000 - 999)
1.00
632
(0.00 - 10.00)
0.00
632
(-10.00 - +10.00)
0
632
(0, 1)
0
633
(0, 1)
407