YASKAWA GA700 Technical Manual page 345

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

2.
Lift up directly on the cooling fan. Unplug the power supply connector and release the fan from the drive.
A - Cooling fan
Install a Fan
Reverse the removal procedure to reinstall the cooling fan.
1.
Install the replacement cooling fan into the drive, ensuring the protrusions on the drive line up with the
notches on the fan.
A - Notch of fan
B - Protrusions of drive
2.
Properly connect the fan power lines, then place the cable back into the recess of the drive.
A - Drive front surface
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Figure 7.7 Remove a Cooling Fan
Figure 7.8 Install a Cooling Fan
Figure 7.9 Connect Cooling Fan Power Supply Connectors
7.4 Replace a Cooling Fan and Circulation Fan
C - Drive front surface
7
345

Advertisement

Table of Contents
loading

Table of Contents