11.8 H: Terminal Functions
H2-63: Terminal M3-M4 Function B Select
No.
Name
(Hex.)
H2-63
Terminal M3-M4
Function B Select
(1B49)
H2-64: Terminal M3-M4 Logical Operation
No.
Name
(Hex.)
H2-64
Terminal M3-M4
Logical Operation
(1B4A)
Note:
Refer to Output of Logical Calculation Results of MFDO on page 778
settings and logical operations.
H2-65: Terminal M3-M4 Delay Time
No.
Name
(Hex.)
H2-65
Terminal M3-M4
Delay Time
(1B4B)
H2-66: Terminal M5-M6 Function B Select
No.
Name
(Hex.)
H2-66
Terminal M5-M6
Function B Select
(1B4C)
H2-67: Terminal M5-M6 Logical Operation
No.
Name
(Hex.)
H2-67
Terminal M5-M6
Logical Operation
(1B4D)
Note:
Refer to Output of Logical Calculation Results of MFDO on page 778
settings and logical operations.
H2-68: Terminal M5-M6 Delay Time
No.
Name
(Hex.)
H2-68
Terminal M5-M6
Delay Time
(1B4E)
784
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal M3-M4. The logical calculation
results of the terminals assigned to functions by H2-02 [Terminal M3-M4
Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-02
[Terminal M3-M4 Function Select] and H2-63 [Terminal M3-M4 Function
B Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical calculation
results from terminal M3-M4.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal P1-C1. The logical calculation
results of the terminals assigned to functions by H2-03 [Terminal P1-PC
Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-03
[Terminal P1-PC Function Select] and H2-66 [Terminal M5-M6 Function B
Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical calculation
results from terminal P1-C1.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
for more information on the relationship between parameter
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
for more information on the relationship between parameter
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
F
(0 - A7)
Default Setting
(Range)
0
(0 - 8)
Default Setting
(Range)
0.1 s
(0.0 - 25.0 s)
Default Setting
(Range)
F
(0 - A7)
Default Setting
(Range)
0
(0 - 8)
Default Setting
(Range)
0.1 s
(0.0 - 25.0 s)

Advertisement