bUS appears on the keypad, and operation continues.
Note:
Prepare safety protection equipment and systems such as fast stop switches separately.
F6-04: bUS Error Detection Time
No.
Name
(Hex.)
F6-04
bUS Error Detection
Time
(03A5)
Note:
The setting value changes to 0.0 s when the option card is mounted in the drive.
F6-06: Torque Reference/Limit by Comm
No.
Name
(Hex.)
F6-06
Torque Reference/
Limit by Comm
(03A7)
0 : Disabled
1 : Enabled
F6-07: Multi-Step Ref @ NetRef/ComRef
No.
Name
(Hex.)
F6-07
MultiStep Ref
Priority Select
(03A8)
0 : MultiStep References Disabled
The multi-step speed reference (2-step speed to 16-step speed references) and the Jog Frequency Reference (JOG
command) are disabled when NetRef or ComRef is selected as the frequency reference source.
1 : MultiStep References Enabled
The multi-step speed reference (2-step speed through 16-step speed references) and the Jog Frequency Reference
(JOG command) are enabled, and the frequency reference can be changed when NetRef or ComRef is selected as
the frequency reference source.
F6-08: Comm Parameter Reset @Initialize
No.
Name
(Hex.)
F6-08
Comm Parameter
Reset @Initialize
(036A)
Note:
The setting value of F6-08 is not changed when the drive is initialized by A1-03 when F6-08 = 1.
0 : No Reset - parameters retained
1 : Reset - back to factory default
F6-10: CC-Link Node Address
No.
Name
(Hex.)
F6-10
CC-Link Node
Address
(03B6)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time until bUS [Option Communication Error] issues are
detected.
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to enable or disable the torque reference and torque limit
received from the communication option card.
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to enable/disable the multi-step speed reference when
NetRef (communication option card) or ComRef (MEMOBUS/Modbus
communications) is selected as the frequency reference source.
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether or not to initialize communication parameters [F6-xx and
F7-xx] when the drive is initialized by A1-03 [Initialize Parameters].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the node address for CC-Link communication. The drive must be
restarted when the setting is changed.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.7 F: Options
Default Setting
(Range)
2.0 s
(0.0 - 5.0 s)
Default Setting
(Range)
0
(0, 1)
Default Setting
(Range)
0
(0, 1)
Default Setting
(Range)
0
(0, 1)
Default Setting
(Range)
0
(0 - 64)