No.
Name
(Hex.)
U6-27
FF Estimate SPD
(006D)
U6-36
Comm Errors-
HOST
(0720)
U6-37
Comm Errors-
Sensor
(0721)
U6-48
ASIC Comm
Errors
(072E)
U6-57
PoleDis IdDifVal
(07C4)
U6-80 to
OPT IP ADR1 to 4
U6-83
(07B0 to
07B3)
U6-84 to
Online Subnets 1
U6-87
to 4
(07B4 to
07B7)
U6-88 to
Online Gateways 1
U6-91
to 4
(07B8 to
07F1)
U6-92
Online Speed
(07F2)
U6-93
Online Duplex
(07F3)
U6-98
First Fault
(07F8)
U6-99
Current Fault
(07F9)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Displays the feed forward estimated speed.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Counts the number of inter-CPU communication errors. This count
is reset to 0 when the power to the drive is turned off.
V/f
CL-V/f
OLV
CLV
AOLV
Counts the number of inter-CPU communication errors. This count
is reset to 0 when the power to the drive is turned off.
V/f
CL-V/f
OLV
CLV
AOLV
Counts the number of inter-ASIC communication errors detected by
the ASIC. This count is reset to 0 when the power to the drive is
turned off.
V/f
CL-V/f
OLV
CLV
AOLV
Displays the deviation from the integrated current when determining
the polarity.
Unit: 1
Note:
If the deviation from the integrated current is lower than 819,
then increase the value set to n8-84
[InitPolarityEstimationTimeoutCur]. U6-57 = 8192 is equivalent
to the motor rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Displays the currently available local IP Address.
• U6-80: 1st octet
• U6-81: 2nd octet
• U6-82: 3rd octet
• U6-83: 4th octet
V/f
CL-V/f
OLV
CLV
AOLV
Displays the currently available subnet mask.
• U6-84: 1st octet
• U6-85: 2nd octet
• U6-86: 3rd octet
• U6-87: 4th octet
V/f
CL-V/f
OLV
CLV
AOLV
Displays the currently available gateway address.
• U6-88: 1st octet
• U6-89: 2nd octet
• U6-90: 3rd octet
• U6-91: 4th octet
V/f
CL-V/f
OLV
CLV
AOLV
Displays the currently available communications speed.
10: 10 Mbps
100: 100 Mbps
V/f
CL-V/f
OLV
CLV
AOLV
Displays the currently available Duplex setting.
V/f
CL-V/f
OLV
CLV
AOLV
Displays the contents of previous fault from communication options
(DeviceNet, Modbus TCP/IP, EtherNet/IP).
V/f
CL-V/f
OLV
CLV
AOLV
Displays the contents of current faults from communication options
(DeviceNet, Modbus TCP/IP, EtherNet/IP).
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.17 U: Monitors
MFAO Signal
Ref.
Level
10 V = Maximum
-
frequency
(-10 V to +10 V)
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
509
10

Advertisement

Table of Contents
loading

Table of Contents