High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

Note:
• Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
• The configurable monitor varies depending on the control method.
H2-21: Comparator 1 Lower Limit
No.
Name
(Hex.)
H2-21
Comparator 1 Lower
Limit
(1541)
Note:
Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
H2-22: Comparator 1 Upper Limit
No.
Name
(Hex.)
H2-22
Comparator 1 Upper
Limit
(1542)
Note:
Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
H2-23: Comparator 1 Hysteresis
No.
Name
(Hex.)
H2-23
Comparator 1
Hysteresis
(1543)
Note:
Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
H2-24: Comparator 1 On-Delay Time
No.
Name
(Hex.)
H2-24
Comparator 1 On-
Delay Time
(1544)
Note:
Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
H2-25: Comparator 1 Off-Delay Time
No.
Name
(Hex.)
H2-25
Comparator 1 Off-
Delay Time
(1545)
Note:
Refer to H2-xx = 66 and 67 [Multi-Function Digital Out Function Select = Comparator1 and Comparator 2] for more information on
the comparator function.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Configures the lower limit detection level for comparator 1 on the basis that
the full scale analog output for the monitor number selected with H2-20
[Comparator 1 Monitor Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the upper limit detection level for comparator 1 on the basis that
the full scale analog output for the monitor number selected with H2-20
[Comparator 1 Monitor Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the hysteresis level for comparator 1 on the basis that the full
scale analog output for the monitor number selected with H2-20
[Comparator 1 Monitor Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the comparator 1 on delay time.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the comparator 1 off delay time.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.8 H: Terminal Functions
Default Setting
(Range)
0.0%
(0.0 - 300.0%)
Default Setting
(Range)
0.0%
(0.0 - 300.0%)
Default Setting
(Range)
0.0%
(0.0 - 10.0%)
Default Setting
(Range)
0.0 s
(0.0 - 600.0 s)
Default Setting
(Range)
0.0 s
(0.0 - 600.0 s)