O2: Keypad Operation - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.13 o: Keypad-Related Settings

o2: Keypad Operation

No.
Name
(Hex.)
o2-01
LO/RE Key
Function Selection Selects whether to enable or disable switching between local and
(0505)
o2-02
STOP Key
Function Selection
(0506)
o2-03
User Parameter
Default Value
(0507)
o2-04
Drive Model
Selection
(0508)
o2-05
Freq Ref Setting
Method Select
(0509)
o2-06
Ope Select
@Keypad is
(050A)
Disconnect
o2-07
MotorDirect@Po
wUpWhenUsing
(0527)
Keypad
o2-09
Factory use
(050D)
o2-23
Lost Detection of
Ext. Power 24V
(11F8)
o2-24
LED Light
Function Selection Selects the option to enable or disable the LED status rings and LED
(11FE)
486
Description
V/f
CL-V/f
OLV
CLV
AOLV
remote modes via
.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether or not to enable functionality of the
keypad when the Run command source for the drive is set to
REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Changed parameter setting values are stored as the user parameter
default settings used when the drive is initialized.
0 : No change
1 : Set defaults
2 : Clear all
V/f
CL-V/f
OLV
CLV
AOLV
Configures the Drive Model code for the corresponding Drive
Model. This parameter must be configured when control boards are
replaced.
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether or not the
frequency reference value with the keypad when in Drive Mode.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether or not to stop the drive when the keypad connection
cable is disconnected from the drive or damaged while the keypad is
the Run command source.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects the direction of motor rotation when the power is turned on
when the keypad is the Run command source.
0 : Forward
1 : Reverse
-
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether or not to provide warning when the backup external
24-V power supply turns off while the main circuit power supply is
supplied.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
lamps on the keypad.
0 : Both Enable
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
on the
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
must be pressed to change the
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
1
903
(0, 1)
1
903
(0, 1)
0
904
(0 - 2)
Determined by the
904
drive
(-)
0
904
(0, 1)
0
905
(0, 1)
0
905
(0, 1)
-
-
0
905
(0, 1)
0
906
(0 - 2)

Advertisement