YASKAWA GA700 Technical Manual page 645

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

C1-01: Acceleration Time 1
No.
Name
(Hex.)
C1-01
Acceleration Time 1
(0200)
RUN
Note:
If C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range will be 0.00 to 600.00 s.
C1-02: Deceleration Time 1
No.
Name
(Hex.)
C1-02
Deceleration Time 1
(0201)
RUN
Note:
If C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range will be 0.00 to 600.00 s.
C1-03: Acceleration Time 2
No.
Name
(Hex.)
C1-03
Acceleration Time 2
(0202)
RUN
Note:
If C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range will be 0.00 to 600.00 s.
C1-04: Deceleration Time 2
No.
Name
(Hex.)
C1-04
Deceleration Time 2
(0203)
RUN
Note:
If C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range will be 0.00 to 600.00 s.
C1-05: Acceleration Time 3
No.
Name
(Hex.)
C1-05
Acceleration Time 3
(0204)
RUN
Note:
If C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range will be 0.00 to 600.00 s.
C1-06: Deceleration Time 3
No.
Name
(Hex.)
C1-06
Deceleration Time 3
(0205)
RUN
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time it takes to accelerate from zero to the maximum output
frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time it takes to decelerate from the maximum output frequency to
zero.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to accelerate from 0 to maximum frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to decelerate from maximum frequency to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to accelerate from 0 to maximum frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to decelerate from maximum frequency to 0.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.4 C: Tuning
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
11