D7: Offset Frequency - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.5 d: Reference Settings
Note:
The field forcing function is disabled for DC Injection Braking.

d7: Offset Frequency

Adds or subtracts the set frequency (Offset frequency) to/from the frequency reference using 3 digital signal
inputs, and corrects the speed. Selects the Offset frequency using the terminal set in H1-xx = 44 to 46 [MFDI
Function Select = Offset frequency 1 to 3]. The selected offset values are added together if multiple inputs are
closed simultaneously.
The following diagram illustrates the Offset frequency function.
d7-01: Offset Frequency 1
No.
Name
(Hex.)
d7-01
Offset Frequency 1
(02B2)
RUN
d7-02: Offset Frequency 2
No.
Name
(Hex.)
d7-02
Offset Frequency 2
(02B3)
RUN
d7-03: Offset Frequency 3
No.
Name
(Hex.)
d7-03
Offset Frequency 3
(02B4)
RUN
688
Figure 11.67 Offset Frequency Operation
V/f
CL-V/f
OLV
CLV
AOLV
Adds or subtracts the set frequency to/from the frequency reference using
H1-xx = 44 [MFDI Function Select = Offset frequency 1] as a percentage of
the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Adds or subtracts the set frequency to/from the frequency reference using
H1-xx = 45 [MFDI Function Select = Offset frequency 2] as a percentage of
the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Adds or subtracts the set frequency to/from the frequency reference using
H1-xx = 46 [MFDI Function Select = Offset frequency 3] as a percentage of
the maximum output frequency.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0.0%
(-100.0 - +100.0%)
Default Setting
(Range)
0.0%
(-100.0 - +100.0%)
Default Setting
(Range)
0.0%
(-100.0 - +100.0%)

Advertisement

Table of Contents
loading

Table of Contents