10.13 o: Keypad-Related Settings
No.
Name
(Hex.)
o4-07
DCBusPreChargeR
elayMainteSetting
(0523)
o4-09
IGBT Maintenance
Setting
(0525)
o4-11
U2, U3
Initialization
(0510)
o4-12
kWh Monitor
Initialization
(0512)
o4-13
NumOfRunCom
mands Counter
(0528)
Initial
o4-22
Time Format
(154F)
o4-23
Date Format
(1550)
o4-24
bAT Detection
Operation
(310F)
Selection
RUN

o5: Log Function

No.
Name
(Hex.)
o5-01
Log Start/Stop
Selection
(1551)
RUN
o5-02
Log Sampling
Interval
(1552)
RUN
o5-03
Log Monitor Data
1
(1553)
RUN
o5-04
Log Monitor Data
2
(1554)
RUN
488
Description
V/f
CL-V/f
OLV
CLV
AOLV
U4-06 [SChgBypassRelayMaint] monitor values can be overwritten.
V/f
CL-V/f
OLV
CLV
AOLV
U4-07 [IGBT Maintenance] monitor values can be overwritten.
V/f
CL-V/f
OLV
CLV
AOLV
Resets the records of Monitors U2-xx [Fault Trace] and U3-xx
[Fault History].
0 : No Reset
1 : Reset
V/f
CL-V/f
OLV
CLV
AOLV
Resets the monitor values for U4-10 [kWh, Lower 4 Digits] and U4-
11 [kWh, Upper 5 Digits].
0 : No Reset
1 : Reset
V/f
CL-V/f
OLV
CLV
AOLV
Resets the monitor values for U4-02 [Num of Run Commands], U4-
24 [No of Travels(L)], and U4-25 [No of Travels(H)].
0 : No Reset
1 : Reset
V/f
CL-V/f
OLV
CLV
AOLV
Selects the time display format. This parameter is only enabled for
LED keypads.
0 : 24 hour clock
1 : 12 hour EA clock
2 : 12 hour JP clock
V/f
CL-V/f
OLV
CLV
AOLV
Selects the date display format. This parameter is only enabled for
LED keypads.
0 : YYYY/MM/DD(2016/01/31)
1 : DD/MM/YYYY(31/01/2016)
2 : MM/DD/YYYY(01/31/2016)
V/f
CL-V/f
OLV
CLV
AOLV
Selects the operation performed when bAT (low keypad battery)
faults are detected.
0 : Disabled
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Starts or stops the data log function. This parameter is only enabled
for LED keypads.
0 : OFF
1 : ON
V/f
CL-V/f
OLV
CLV
AOLV
Selects the data log sampling cycle. This parameter is only enabled
for LED keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for
LED keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the data log monitor. This parameter is only enabled for
LED keypads.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0%
908
(0 - 150%)
0%
909
(0 - 150%)
0
909
(0, 1)
0
909
(0, 1)
0
909
(0, 1)
0
910
(0 - 2)
0
910
(0 - 2)
0
910
(0, 1)
Default
Ref.
(Range)
0
913
(0, 1)
1000 ms
913
(100 - 60000 ms)
101
913
(000,101 - 855)
102
914
(000,101 - 855)