YASKAWA GA700 Technical Manual page 706

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.6 E: Motor Parameters
• PM Rotational Auto-Tuning
Note:
Display is in the following units:
• 2004 to 2042, 4002 to 4023: 0.01 A units
• 2056 to 2415, 4031 to 4675: 0.1 A units
E5-04: PM Motor Pole Count
No.
Name
(Hex.)
E5-04
PM Motor Pole
Count
(032C)
The value of E5-04 is automatically set to the value input for [Number of PM Motor Poles] by the Auto-Tuning
process when the following types of Auto-Tuning processes are performed.
• PM Motor Parameter Settings
• PM Stationary Auto-Tuning
• PM Rotational Auto-Tuning
E5-05: PM Motor Resistance (ohms/phase)
No.
Name
(Hex.)
E5-05
PM Motor Resistance
(ohms/phase)
(032D)
The value of E5-05 is automatically set to the value input for [PM Motor Stator Resistance] by the Auto-Tuning
process for PM motor parameter settings. Parameter E5-05 is configured with the result of all other Auto-Tuning
processes.
Note:
Do not haphazardly change the resulting settings of the Auto-Tuning process.
E5-06: PM d-axis Inductance (mH/phase)
No.
Name
(Hex.)
E5-06
PM d-axis Inductance
(mH/phase)
(032E)
The value of E5-06 is automatically set to the value input for [PM Motor d-Axis Inductance] by the Auto-Tuning
process for PM motor parameter settings. Parameter E5-06 is configured with the result of all other Auto-Tuning
processes.
Note:
Do not haphazardly change the resulting settings of the Auto-Tuning process.
E5-07: PM q-axis Inductance (mH/phase)
No.
Name
(Hex.)
E5-07
PM q-axis Inductance
(mH/phase)
(032F)
The value of E5-07 is automatically set to the value input for [PM Motor q-Axis Inductance] by the Auto-Tuning
process for PM motor parameter settings. Parameter E5-07 is configured with the result of all other Auto-Tuning
processes.
Note:
Do not haphazardly change the resulting settings of the Auto-Tuning process.
706
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PM motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the resistance per phase of the PM motors. Do not enter the line-to-line
resistance into E5-05 when measuring the resistance manually.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor d-Axis inductance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor q-Axis inductance.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
Determined by E5-01
(2 - 48)
Default
(Range)
Determined by E5-01
(0.000 - 65.000 Ω)
Default
(Range)
Determined by E5-01
(0.00 - 300.00 mH)
Default
(Range)
Determined by E5-01
(0.00 - 600.00 mH)