E3-01 (Motor 2 Control Mode) Dependent Parameters - YASKAWA FSDrive-MV1000 Parameter Manual

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

◆ E3-01 (Motor 2 Control Mode) Dependent Parameters

Table 1.3 E3-01 (Motor 2 Control Mode) Dependent Parameters and Default Values
No.
C3-21
Motor 2 Slip Compensation Gain
C5-21
Motor 2 ASR Proportional Gain 1
C5-22
Motor 2 ASR Integral Time 1
C5-23
Motor 2 ASR Proportional Gain 2
C5-24
Motor 2 ASR Integral Time 2
C5-26
Motor 2 ASR Primary Delay Time Constant
E3-04
Motor 2 Maximum Output Frequency
E3-05
Motor 2 Maximum Voltage
E3-06
Motor 2 Base Frequency
E3-07
Motor 2 Mid Output Frequency
E3-08
Motor 2 Mid Output Frequency Voltage
E3-09
Motor 2 Minimum Output Frequency
E3-10
Motor 2 Minimum Output Frequency Voltage
YASKAWA ELECTRIC EZZ010930 FSDrive-MV1000 Parameter Guide
Name
1.4 Control Mode Dependent Parameter Default Values
Setting Range
Resolution
0.0 to 2.5
0.1
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.00 to 300.00
0.01
0.000 to 10.000
0.001 s
0.0 to 0.500
0.001 s
40.0 to 120.0
0.1 Hz
0 to 13000
1 V
0.0 to 120.0
0.1 Hz
0.0 to 120.0
0.1 Hz
0 to 13000
1 V
0.0 to 120.0
0.1 Hz
0 to 13000
1 V
Control Modes (E3-01)
V/f (0)
OLV (2)
CLV (3)
0.0
1.0
1.0
5.00
5.000
5.00
5.000
0.004
60.0
60.0
60.0
2000
2000
2000
60.0
60.0
60.0
3.0
3.0
0.0
150
110
0
1.5
0.5
0.0
90
20
0
81

Advertisement

Table of Contents
loading

Table of Contents