11.10 n: Special Adjustment
n8-14: Polarity Compensation Gain 3
No.
Name
(Hex.)
n8-14
Polarity
Compensation Gain 3 Sets the gain for speed estimation. Normally there is no need to change this
(054D)
n8-15: Polarity Compensation Gain 4
No.
Name
(Hex.)
n8-15
Polarity
Compensation Gain 4 Sets the gain for speed estimation. Normally there is no need to change this
(054E)
n8-21: Motor Ke Gain
No.
Name
(Hex.)
n8-21
Motor Ke Gain
(0554)
n8-35: InitRotorPosition Detect Select
No.
Name
(Hex.)
n8-35
InitRotorPosition
Detect Select
(0562)
When A1-02 = 7 [Control Method Selection = PM Closed Loop Vector Control] is set, the initial motor magnetic
pole detection operates for the first instance after the power supply is turned on. After that, rotor position is
calculated from the encoder signal and saved until the drive is switched off.
0 : Pull-In
Starts the rotor with pull-in current.
1 : High frequency injection
High frequency is injected to detect the rotor position. Using this setting may cause significant excitation sound
when motors start.
2 : Pulse injection
Inputs the pulse signal to the motor to detect the position of the rotor.
Note:
• Select a value of 0 if using SPM motors. Values between 0 to 2 can be selected if using IPM motors.
• Always carry out a prior evaluation of the drive and machinery combination being used for the application when setting n8-35 = 1 or 2.
The motor may rotate in the direction that is opposite that of the direction of the Run command if the polarity direction is detected
mistakenly.
n8-36: InjectionSignalFreqForInductTurn
No.
Name
(Hex.)
n8-36
InjectionSignalFreq
ForInductTurn
(0563)
Calculated automatically when PM Rotational Auto-Tuning or PM Stationary Auto-Tuning is carried out.
890
V/f
CL-V/f
OLV
CLV
AOLV
setting.
V/f
CL-V/f
OLV
CLV
AOLV
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Normally there is no need to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Selects how the rotor position is detected at start.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the injection frequency for high frequency injection.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
1.000
(0.000 - 10.000)
Default Setting
(Range)
0.500
(0.000 - 10.000)
Default Setting
(Range)
0.90
(0.80 - 1.00)
Default Setting
(Range)
Determined by A1-02
(0 - 2)
Default Setting
(Range)
500 Hz
(200 - 5000 Hz)