No.
Name
(Hex.)
F7-12
Gateway Address 4
(03F0)
F7-13
Address Mode at
Startup
(03F1)
F7-14
Duplex Mode
Selection
(03F2)
F7-15
Communication
Speed Selection
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
EtherNet/IP Speed
Scaling Factor
(03F5)
F7-18
EtherNet/IP
Current Scale
(03F6)
Factor
F7-19
EtherNet/IP Torque
Scale Factor
(03F7)
F7-20
EtherNet/IP Power
Scaling Factor
(03F8)
F7-21
EtherNet/IP
Voltage Scale
(03F9)
Factor
F7-22
EtherNet/IP Time
Scaling
(03FA)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Gateway address for the connected network. Sets the fourth
octet.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup =
Static].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the method to set addresses for option cards.
0 : Static
1 : BOOTP
2 : DHCP
Note:
• The following setting values are available when using the
PROFINET communication option card (SI-EP3).
0: Static
2: DCP
• Set F7-01 through F7-12 [IP Address 1 = Gateway Address 4]
when F7-13 = 0. Set the IP Addresses so that they do not
overlap on the same network.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the setting method for the duplex mode.
0 : Auto/Auto
1 : Half/Half
2 : Full/Full
V/f
CL-V/f
OLV
CLV
AOLV
Sets the communications speed.
10 : 10/10 Mbps
102 : 100/100 Mbps
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time of the timeout value for communications in
increments of 0.1 s.
Note:
Setting this parameter to 0 disables the connection timeout
function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the speed monitor for the EtherNet/IP
object with the Class ID 2AH.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the output current monitor for the
EtherNet/IP object with the Class ID 2AH.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the torque monitor for the EtherNet/IP
object with the Class ID 2AH.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the power monitor for the EtherNet/IP
object with the Class ID 2AH.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the voltage monitor for the EtherNet/IP
object with the Class ID 2AH.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the time monitor for the EtherNet/IP
object with the Class ID 2AH.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.9 F: Options
Default
Ref.
(Range)
1
746
(0 to 255)
2
746
(0 - 2)
1
747
(0 - 8)
10
747
(10, 102)
0.0 s
747
(0.0 to 30.0 s)
0
747
(-15 to 15)
0
747
(-15 to 15)
0
748
(-15 to 15)
0
748
(-15 to 15)
0
748
(-15 to 15)
0
748
(-15 to 15)