YASKAWA GA700 Technical Manual page 701

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

E3-05: Motor 2 Maximum Output Voltage
No.
Name
(Hex.)
E3-05
Motor 2 Maximum
Output Voltage
(031B)
E3-06: Motor 2 Base Frequency
No.
Name
(Hex.)
E3-06
Motor 2 Base
Frequency
(031C)
E3-07: Motor 2 Mid Point A Frequency
No.
Name
(Hex.)
E3-07
Motor 2 Mid Point A
Frequency
(031D)
E3-08: Motor 2 Mid Point A Voltage
No.
Name
(Hex.)
E3-08
Motor 2 Mid Point A
Voltage
(031E)
E3-09: Motor 2 Minimum Output Frequency
No.
Name
(Hex.)
E3-09
Motor 2 Minimum
Output Frequency
(031F)
E3-10: Motor 2 Minimum Output Voltage
No.
Name
(Hex.)
E3-10
Motor 2 Minimum
Output Voltage
(0320)
E3-11: Motor 2 Mid Point B Frequency
No.
Name
(Hex.)
E3-11
Motor 2 Mid Point B
Frequency
(0345)
Note:
• Parameter E3-11 is disabled when this parameter is set to 0.0.
• This parameter is reset to the default value when the drive is initialized.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the middle output frequency used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the middle output frequency voltage used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mid point B frequency used for motor 2. Configure this parameter
only when the V/f pattern for the constant output range needs to be adjusted.
Normally there is no need to configure this setting.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.6 E: Motor Parameters
Default Setting
(Range)
Determined by E3-01
(200 V Class: 0.0 to
255.0 V,
400 V Class: 0.0 to
510.0 V)
Default Setting
(Range)
Determined by E3-01
(0.0 to E3-04)
Default Setting
(Range)
Determined by E3-01
(0.0 to E3-04)
Default Setting
(Range)
Determined by E3-01
(200 V Class: 0.0 to
255.0 V,
400 V Class: 0.0 to
510.0 V)
Default Setting
(Range)
Determined by E3-01
(0.0 to E3-04)
Default Setting
(Range)
Determined by E3-01
(200 V Class: 0.0 to
255.0 V,
400 V Class: 0.0 to
510.0 V)
Default Setting
(Range)
0.0 Hz
(0.0 to E3-04)