YASKAWA GA700 Technical Manual page 753

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

Setting
45
Offset Frequency 2
46
Offset Frequency 3
47
Node Setup
60
DC Injection Braking Command
61
External Speed Search Command 1:
Maximum Output Frequency
62
External Speed Search Command 2: Set
Frequency Reference
63
Field Weakening
65
KEB Ride-Thru 1 (N.C.)
*1
66
KEB Ride-Thru 1 (N.O.)
*1
67
Communications Test Mode
68
High-Slip Braking
6A
Drive Enable
71
Speed/Torque Control Switch
72
Zero Servo
*1
Input inversion is not available.
H1-01: Terminal S1 Function Select
No.
Name
(Hex.)
H1-01
Terminal S1 Function
Select
(0438)
Note:
When Initialization [A1-03 = 3330] has been performed for a 3-wire sequence, the default setting is F.
H1-02: Terminal S2 Function Select
No.
Name
(Hex.)
H1-02
Terminal S2 Function
Select
(0439)
Note:
When Initialization [A1-03 = 3330] has been performed for a 3-wire sequence, the default setting is F.
H1-03: Terminal S3 Function Select
No.
Name
(Hex.)
H1-03
Terminal S3 Function
Select
(0400)
H1-04: Terminal S4 Function Select
No.
Name
(Hex.)
H1-04
Terminal S4 Function
Select
(0401)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Function
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S2.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S3.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S4.
Setting
75
Up 2 Command
76
Up 2 Command
77
ASR Gain Switch
78
Ex.Torque Ref Polarity Inversion
7A
KEB Ride-Thru 2 (N.C.)
*1
7B
KEB Ride-Thru 2 (N.O.)
*1
7C
Short Circuit Braking (N.O.)
*1
7D
Short Circuit Braking (N.C.)
*1
7E
FWD/REV Detect (V/f w/ simplePG)
90 to 97
DriveWorksEZ Digital Inputs 1 to 8
*1
9F
DriveWorksEZ Disable
1xx
0 to 9F Input Inversion
Performs input inversion on the function of
the selected MFDI. Input two digits 00 to 9F
in place of the two Xs in 1xx to select the
function that will undergo input inversion.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
11.8 H: Terminal Functions
Function
Default
(Range)
40
(1-19F)
Default Setting
(Range)
41
(1 - 19F)
Default Setting
(Range)
24
(0 - 19F)
Default Setting
(Range)
14
(0 - 19F)
11
753

Advertisement

Table of Contents
loading

Table of Contents