4.2 European Standards
Model
Terminal
R/L1, S/L2, T/
L3
U/T1, V/T2, W/
T3
2360
-, +1
+3
R/L1, S/L2, T/
L3
U/T1, V/T2, W/
T3
2415
-, +1
+3
*1
Remove the insulator from the tips of wires to the length shown in "Wire Stripping Length."
*2
When using wire with a gauge over 30 mm
*3
Install ELCB to maintain compliance with IEC/EN 61800-5-1:2007 with use of wire of this gauge.
Table 4.3 Wire Gauges and Tightening Torques for 400 V Class Drives
Model
Terminal
R/L1, S/L2, T/
L3
U/T1, V/T2, W/
T3
4002
-, +1, +2
B1, B2
R/L1, S/L2, T/
L3
U/T1, V/T2, W/
T3
4004
-, +1, +2
B1, B2
186
For Europe and China
Recommen
Wire Range
ded Gauge
mm
2
mm
2
2
, tighten to a tightening torque of 4.1 to 4.5 N∙m (36 to 40 lb∙in.).
For Europe and China
Recommen
Wire Range
ded Gauge
mm
2
mm
2
2.5
2.5 - 10
2.5
2.5 - 10
2.5
2.5 - 16
2.5
2.5 - 4
2.5
2.5 - 4
*3
2.5
2.5 - 10
2.5
2.5 - 10
2.5
2.5 - 16
2.5
2.5 - 4
2.5
2.5 - 4
*3
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Wire
Terminal Screw
Stripping
Length
Size
mm
*1
Preparing
Preparing
Wire
Terminal Screw
Stripping
Length
Size
mm
*1
10
M4
10
M4
18
M5
10
M4
-
M4
10
M4
10
M4
18
M5
10
M4
-
M4
Tightening
Torque
Shape
N∙m (lb∙in)
Tightening
Torque
Shape
N∙m (lb∙in)
1.5 - 1.7
Slot (-)
(13.5 - 15)
1.5 - 1.7
Slot (-)
(13.5 - 15)
2.3 - 2.5
Slot (-)
(19.8 - 22)
*2
1.5 - 1.7
Slot (-)
(13.5 - 15)
1.2 - 1.5
Phillips/slot
combo
(10.6 - 13.3)
1.5 - 1.7
Slot (-)
(13.5 - 15)
1.5 - 1.7
Slot (-)
(13.5 - 15)
2.3 - 2.5
Slot (-)
(19.8 - 22)
*2
1.5 - 1.7
Slot (-)
(13.5 - 15)
1.2 - 1.5
Phillips/slot
combo
(10.6 - 13.3)