YASKAWA GA700 Technical Manual page 923

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

Value set in T4-01
0
1
*1
Input using the setup wizard can be skipped when using a PM motor or a synchronous reluctance motor. The drive will automatically
calculate the rated frequency based on the rated rotation speed and number of motor poles that have been input.
*2
The drive will automatically calculate the motor rated slip based on the rated rotation speed, rated frequency, and number of motor
poles that have been input. The setting values can also be entered manually.
T4-01: EZ Tuning Mode Selection
No.
Name
(Hex.)
T4-01
EZ Tuning Mode
Selection
(3130)
0 : Motor constant setting Auto-Tuning
1 : Stationary Auto-Tuning for Line-to-Line Resistance
T4-02: Motor Type Selection
No.
Name
(Hex.)
T4-02
Motor Type Selection
(3131)
0 : IM
1 : PM
2 : SynRM
T4-03: Motor Max Revolutions
No.
Name
(Hex.)
T4-03
Motor Max
Revolutions
(3132)
T4-04: Motor Rated Revolutions
No.
Name
(Hex.)
T4-04
Motor Rated
Revolutions
(3133)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Operational overview
Manually enter the required
motor parameters by following
the instructions presented by the
setup wizard on the keypad.
Perform only line-to-line
resistance tuning.
V/f
CL-V/f
OLV
CLV
Selects the Auto-Tuning method used for EZ Open Loop Vector Control.
V/f
CL-V/f
OLV
CLV
Selects the type of motor.
V/f
CL-V/f
OLV
CLV
Sets the motor max revolutions (min
V/f
CL-V/f
OLV
CLV
Sets rated rotation speed of the motor (min
Items input for tuning
• T4-02 [Motor Type Selection]
• T4-03 [Motor Max
Revolutions]
• T4-04 [Rated Speed]
• T4-05 [Motor Rated
Frequency]
*1
• T4-06 [Base Voltage]
• T4-07 [Motor Rated Current]
• T4-08 [Motor Rated Capacity]
• T4-09 [Number of Motor
Poles]
• T4-10 [Motor Rated Slip]
• T4-11 [Motor Line Resistance]
Motor Rated Current
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
-1
).
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
-1
).
11.12 T: Auto-Tuning
Items tuned
• E9-01 [Motor Type Selection]
• E9-02 [Motor Max
Revolutions]
• E9-03 [Rated Speed]
• E9-04 [Motor Rated
Frequency]
• E9-05 [Base Voltage]
• E9-06 [Motor Rated Current
(FLA)]
• E9-07 [Motor Rated Power
(kW)]
• E9-08 [Number of Motor
*2
Poles]
• E9-09 [Motor Rated Slip]
• E9-10 [Line-to-Line
Resistance]
E9-10 [Line-to-Line Resistance]
Default
(Range)
0
(0, 1)
Default Setting
(Range)
0
(0, 1, 2)
Default Setting
(Range)
-
((40 to 120 Hz) × 60
× 2 / E9-08)
Default Setting
(Range)
-
((40 to 120 Hz) × 60
× 2 / E9-08)
11
923