L5: Fault Restart

No.
Name
(Hex.)
L5-01
Number of Auto
Restart Attempts
(049E)
L5-02
AutoRestartFaul
tOutputOpeSelect
(049F)
L5-04
Auto Restart
Interval Time
(046C)
L5-05
Auto Restart
Operation
(0467)
Selection

L6: Torque Detection

No.
Name
(Hex.)
L6-01
Torque Detection
Selection 1
(04A1)
L6-02
Torque Detection
Level 1
(04A2)
L6-03
Torque Detection
Time 1
(04A3)
L6-04
Torque Detection
Selection 2
(04A4)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of that can be automatically performed by the drive.
Sets the number of Auto Restart operations that the drive may
attempt to restart itself.
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to output signals to the MFDO terminal set for
Fault [H2-xx = E] while the drive is executing Auto restart.
0 : Fault output not active
1 : Fault output active
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time interval between each Auto Restart process. This
function is enabled when L5-05 = 1 [Auto Restart Operation
Selection = Use L5-04 Time].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the count method for the Auto Restart operation.
0 : Continuous
1 : Use L5-04 Time
Description
V/f
CL-V/f
OLV
CLV
AOLV
Selects the speed range at which overtorque/undertorque is detected
and the operation of drives (operation status) after detection.
0 : Disabled
1 : OL Alm at SpdAgr
2 : OL Alm dur RUN
3 : OL Flt at SpdAgr
4 : OL Flt dur RUN
5 : UL Alm at SpdAgr
6 : UL Alm dur RUN
7 : UL Flt at SpdAgr
8 : UL Flt dur RUN
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level for Overtorque/Undertorque Detection 1.
This parameter is set on the basis of the drive rated output current as
the 100% value when using V/f Control. This parameter is set on the
basis of the motor rated torque as the 100% value when using vector
control.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for Overtorque/Undertorque Detection 1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the speed range at which overtorque/undertorque is detected
and the operation of drives (operation status) after detection.
0 : Disabled
1 : OL Alm at SpdAgr
2 : OL Alm dur RUN
3 : OL Flt at SpdAgr
4 : OL Flt dur RUN
5 : UL Alm at SpdAgr
6 : UL Alm dur RUN
7 : UL Flt at SpdAgr
8 : UL Flt dur RUN
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.11 L: Protection Function
Default
Ref.
(Range)
0
855
(0 - 10 times)
0
855
(0, 1)
10.0 s
855
(0.5 - 600.0 s)
0
856
(0, 1)
Default
Ref.
(Range)
0
858
(0 - 8)
150%
859
(0 - 300%)
0.1 s
859
(0.0 - 10.0 s)
0
859
(0 - 8)
10
471