YASKAWA GA700 Technical Manual page 780

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.8 H: Terminal Functions
Note:
• Watt hours are not counted when the power value is a negative value (regenerative state).
• Stores the Watt hours while the control power supply to the drive is operating. The Watt hour count is reset when the control power is
cut due to a momentary power loss or other reason.
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
H2-07: MEMOBUS Register1 Address Select
No.
Name
(Hex.)
H2-07
MEMOBUS
Register1 Address
(0B3A)
Select
Configures H2-07 with the address of the register that is output to MEMOBUS Register 1 (H2-07&H2-08) [H2-01
through H2-04 = 62] and configures H2-08 with the bit.
H2-08: MEMOBUS Register 1 Bit Select
No.
Name
(Hex.)
H2-08
MEMOBUS Register
1 Bit Select
(0B3B)
Configures H2-07 with the address of the register that is output to MEMOBUS Register 1 (H2-07&H2-08) [H2-01
through H2-04 = 62] and configures H2-08 with the bit.
H2-09: MEMOBUS Register2 Address Select
No.
Name
(Hex.)
H2-09
MEMOBUS
Register2 Address
(0B3C)
Select
Configures H2-09 with the address of the register that is output to MEMOBUS Register 1 (H2-07&H2-08) [H2-01
through H2-04 = 63] and configures H2-10 with the bit.
H2-10: MEMOBUS Register 2 Bit Select
No.
Name
(Hex.)
H2-10
MEMOBUS Register
2 Bit Select
(0B3D)
Configures H2-09 with the address of the register that is output to MEMOBUS Register 1 (H2-07&H2-08) [H2-01
through H2-04 = 63] and configures H2-10 with the bit.
H2-20: Comparator 1 Monitor Selection
No.
Name
(Hex.)
H2-20
Comparator 1
Monitor Selection
(1540)
780
V/f
CL-V/f
OLV
CLV
AOLV
Configures the address of the MEMOBUS/Modbus register output to the
MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the bit of the MEMOBUS/Modbus register output to the MFDO
terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the address of the MEMOBUS/Modbus register output to the
MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the bit of the MEMOBUS/Modbus register output to the MFDO
terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the monitor number for comparator 1. Configure the x-xx
portion of Ux-xx [Monitor]. For example, set x-xx to 102 to monitor U1-02
[Output Frequency].
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
0001
(0001 - 1FFF)
Default Setting
(Range)
0000
(0000 - FFFF)
Default Setting
(Range)
0001
(0001 - 1FFF)
Default Setting
(Range)
0000
(0000 - FFFF)
Default Setting
(Range)
102
(000 - 999)