Note:
Be sure to perform Auto-Tuning after setting A1-06 for a hoist application.
page 581
for hoist (elevator) instructions.
No.
A1-02
b1-01
b6-01
b6-02
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
E1-03
H2-01
H2-02
H3-06
L2-03
L3-04
L4-01
L4-02
L6-01
L6-02
L6-03
L8-05
L8-07
L8-38
L8-41
The drive saves the following parameters as User Parameters.
Table 11.12 Parameters Saved as User Parameters with the Hoist Preset
User Parameters No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Table 11.11 Optimal Settings for Hoist Applications
Name
Control Method Selection
Frequency Reference Selection 1
Dwell Reference at Start
Dwell Time at Start
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
V/f Pattern Selection
Terminal M1-M2 Function Select
Terminal M3-M4 Function Select
Terminal A3 Function Selection
Momentary Power Loss Min BB Time
Decel Stall Prevention Selection
Speed Agree Detection Level
Speed Agree Detection Width
Torque Detection Selection 1
Torque Detection Level 1
Torque Detection Time 1
Input Phase Loss Protect Select
Output Phase Loss Protect Select
Carrier Frequency Reduction
High Current Alarm Selection
Parameter No. Saved
A1-02
b1-01
b6-01
b6-02
C1-01
C1-02
C6-02
d1-01
d1-02
d1-03
E1-08
11.2 A: Initialization Parameters
Refer to Notes when Applying the Drive to the Elevator on
Optimal Value
2: Open Loop Vector Control
0: Heavy Duty Rating
2: 5.0 kHz (4.0 kHz for AOLV/PM)
F: User Defined (C6-03 to C6-05)
5: Frequency Detection 2
37: During Frequency Output
F: Through Mode
8: UL Flt dur RUN
1: Enabled below 6 Hz
Control Method Selection
Frequency Reference Selection 1
Dwell Reference at Start
Dwell Time at Start
Acceleration Time 1
Deceleration Time 1
Carrier Frequency Selection
Mid Point A Voltage
0: Keypad
3.0 Hz
0.3 s
3.0 s
3.0 s
6.00 Hz
30.00 Hz
60.00 Hz
0.3 s
0: Disabled
2.0 Hz
0.0 Hz
2%
0.5 s
1: Enabled
1: Enabled
1: Enabled
Name
Reference 1
Reference 2
Reference 3