O5: Log Function - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.11 o: Keypad-Related Settings
1 : Reset
Resets the monitor values for U4-02, U4-24, and U4-25. After the reset, the setting value of o4-13 is
automatically reset to 0.
o4-22: Time Format
No.
Name
(Hex.)
o4-22
Time Format
(154F)
The format display of the time that appears in the upper-left of the LCD keypad screen varies depending on the
setting of o4-22.
0 : 24 hour clock
1 : 12 hour EA clock
2 : 12 hour JP clock
o4-23: Date Format
No.
Name
(Hex.)
o4-23
Date Format
(1550)
The date format used in the fault history and such varies depending on the setting of o4-23.
0 : YYYY/MM/DD(2016/01/31)
1 : DD/MM/YYYY(31/01/2016)
2 : MM/DD/YYYY(01/31/2016)
o4-24: bAT Detection Operation Selection
No.
Name
(Hex.)
o4-24
bAT Detection
Operation Selection
(310F)
RUN
0 : Disabled
Do not detect.
1 : Enabled
Detect as a minor fault.

o5: Log Function

The data log function stores drive state information as a CSV file in the micro SD memory card in the keypad.
Monitors Ux-xx are the source of data log information. Up to a maximum of 10 monitors can be recorded.
Change the LCD keypad screen from the main menu to the tools screen and select the data log function.
Configure the number of the monitor to record and the sampling time and then start recording the data log.
No.
o5-03
Log Monitor Data 1
o5-04
Log Monitor Data 2
o5-05
Log Monitor Data 3
o5-06
Log Monitor Data 4
o5-07
Log Monitor Data 5
910
V/f
CL-V/f
OLV
CLV
AOLV
Selects the time display format. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the date display format. This parameter is only enabled for LED
keypads.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the operation performed when bAT (low keypad battery) faults are
detected.
Table 11.63 Setting Parameters for Data Log Items
Name
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
101
U1-01 [Freq Reference]
102
U1-02 [Output Frequency]
103
U1-03 [Output Current]
107
U1-07 [DC Bus Voltage]
108
U1-08 [Output Power]
Default Setting
(Setting Range)
0
(0 - 2)
Default Setting
(Setting Range)
0
(0 - 2)
Default
(Range)
0
(0, 1)
Data log monitors

Advertisement

Table of Contents
loading

Table of Contents