9.6
Drive Derating
The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the
drive capacity.
◆
Carrier Frequency Settings and Rated Current Value
Table 9.10
and
Table 9.11
carrier frequency settings. The output current value changes linearly in accordance with carrier frequency
changes. Frequencies not listed in the following table can also be obtained by performing calculations with the
values listed in the table. Refer to
Control.
Table 9.10 Carrier Frequency and Rated Current Derating (200 V Class)
Model
2 kHz
2004
3.2
2006
5.0
2008
6.9
2010
8.0
2012
11.0
2018
14.0
2021
17.5
2030
25.0
2042
33.0
2056
47.0
2070
2082
2110
2138
2169
2211
2257
2313
2360
2415
Table 9.11 Carrier Frequency and Rated Current Derating (400 V Class)
Model
2 kHz
4002
1.8
4004
3.4
4005
4.8
4007
5.5
4009
7.2
4012
9.2
4018
14.8
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
illustrates the manner in which the drive rated output current changed depending on the
Table 9.12
and
Table 9.13
Heavy Duty Rating (HD1)
8 kHz
10 kHz
3.2
-
5.0
-
6.9
-
8.0
-
11.0
-
14.0
-
17.5
-
25.0
-
33.0
29.3
47.0
43.4
Heavy Duty Rating (HD1)
8 kHz
10 kHz
1.8
-
3.4
-
4.8
-
5.5
-
7.2
-
9.2
-
14.8
13.7
when configured with Advanced Open Loop Vector
Rated Current (A)
15 kHz
2 kHz
2.78
3.5
4.3
6
5.4
8
5.8
9.6
8.8
12
9.1
17.5
12.6
21
18.0
30
-
42
-
56
Preparing
Rated Current (A)
Normal Duty Rating (ND1)
15 kHz
2 kHz
1.0
2.1
1.7
4.1
3.0
5.4
3.2
7.1
4.8
8.9
5.4
11.9
-
17.5
9.6 Drive Derating
Normal Duty Rating (ND1)
8 kHz
15 kHz
2.9
5
6.9
8
11
14
17
25
33
47
8 kHz
10 kHz
15 kHz
1.8
-
3.4
-
4.8
-
5.5
-
7.2
-
9.2
-
14.8
13.7
2.10
3.6
5.4
5.8
9.3
9.1
12.5
18.0
20.4
34.4
1.4
2.4
3.9
9
3.2
4.8
5.4
-
375