10.9 F: Options
No.
Name
(Hex.)
F1-14
PG Open-Circuit
Detection Time
(038D)
F1-18
Deviation 3
Detection Selection Sets the number of rotations to detect scenarios in which the torque
(03AD)
F1-19
Deviation 4
Detection Selection Sets the number of pulses used to detect dv4 [Inversion Prevention
(03AE)
F1-20
PG Option PCB
Disconnect Detect1 Selects whether to enable or disable the disconnection detection
(03B4)
F1-21
PG 1 Signal
Selection
(03BC)
F1-30
Motor 2 PG Option
Port Selection
(03AA)
F1-31
PG 2 Pulses Per
Revolution
(03B0)
F1-32
PG 2 Rotation
Selection
(03B1)
F1-33
PG 2 Gear Teeth 1
(03B2)
F1-34
PG 2 Gear Teeth 2
(03B3)
F1-35
PG2 Division Rate
for Pulse Mon
(03BE)
F1-36
PG Option PCB
Disconnect Detect2 Selects whether to enable or disable the disconnection detection
(03B5)
430
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for PGo [PG Disconnect].
Note:
Faults such as ov [DB Bus Overvoltage] and oC [Overcurrent]
may occur depending on the motor speed and load conditions.
V/f
CL-V/f
OLV
CLV
AOLV
reference and rate of acceleration are inverted, which function as the
detection conditions for dv3 [Inversion Detection].
V/f
CL-V/f
OLV
CLV
AOLV
Detection].
V/f
CL-V/f
OLV
CLV
AOLV
function for the encoder connection cable regarding the PG-X3 and
PG-F3. Detects PGoH [PG Hardware Fault] when F1-20 = 1.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects the type of pulse signal (channel) used for the encoder
option card.
0 : A pulse detection
1 : AB pulse detection
V/f
CL-V/f
OLV
CLV
AOLV
Selects the connector used when the motor 2 encoder option card is
mounted in the drive.
0 : CN5-C
1 : CN5-B
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of output pulses per revolution of the encoder. This
parameter is for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the output sequence for phases A and B of the pulses output
from the encoder, given that the motor is running forward. This
parameter is for motor 2.
0 : Pulse A leads
1 : Pulse B leads
V/f
CL-V/f
OLV
CLV
AOLV
Set the number of gear teeth (gear ratio) between the motor and
encoder, in combination with F1-34 [PG 2 Gear Teeth 2]. F1-33 is
set with the number of gear teeth for the motor side. This parameter
is for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth (gear ratio) between the motor and
encoder, in combination with F1-33 [PG 2 Gear Teeth 1]. F1-34 is
set with the number of gear teeth for the load side. This parameter is
for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the dividing ratio for monitor signals output from the encoder
option card. This parameter is for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
function for the encoder connection cable regarding the PG-X3.
PGoH [PG Hardware Fault] is detected when this parameter is
enabled. This parameter is for motor 2.
0 : Disabled
1 : Enabled
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
2.0 s
715
(0.0 - 10.0 s)
10
715
(0 - 10)
128
715
(0 - 5000)
1
716
(0, 1)
0
716
(0, 1)
1
716
(0, 1)
600 ppr
716
(1 - 60000 ppr)
0
716
(0, 1)
0
717
(0 - 1000)
0
717
(0 - 1000)
001
717
(001 - 032, 102 -
132 (1 - 1/32))
1
717
(0, 1)