YASKAWA GA700 Technical Manual page 482

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.12 n: Special Adjustment
No.
Name
(Hex.)
n8-42
HFI Overlap Pole
Detection iTime
(0569)
n8-45
Spd Feedback
Detect Control
(0538)
Gain
n8-47
Pull-
InCurCompensa
(053A)
tionTime Const
n8-48
Pull-In Current (for
PM Motors)
(053B)
n8-49
d-Axis Cur
forHighEfficiency
(053C)
Cont
n8-51
Accel / Decel Pull-
In Current
(053E)
n8-54
VoltErrorCompen
sationTime Const
(056D)
n8-55
Load Inertia
(056E)
n8-57
High Frequency
Injection
(0574)
n8-62
Output Voltage
Limit (for PM)
(057D)
n8-65
SpdFdbkDetectCtrl
GainduringOVSup Sets the gain of internal speed feedback detection suppression while
(065C)
n8-69
Speed Calculation
Gain
(065D)
n8-72
Speed Estimation
Method Select
(0655)
n8-74
LghtLoadCurLvl 1
(05C3)
482
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the oscillation suppression gain of the speed estimation for high
frequency injection. Normally there is no need to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the internal speed feedback detection reduction unit gain as a
magnification value. Normally there is no need to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant used to match the pull-in current reference
value with the actual current value. Normally there is no need to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
On the basis that parameter E5-03 [Motor Rated Current (FLA)] is
the 100% value, this parameter sets the d-axis current that flows to
the motor during run at constant speed as a percentage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets, in terms of a percentage, the d-axis current to be supplied to
the motor to run it at a uniform speed with a heavy load. Considers
E5-03 [Motor Rated Current] to be 100%. Normally there is no
need to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets, as a percentage, the pull-in current allowed to flow during
acceleration/deceleration, taking the motor rated current as a value
of 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant used when compensating for voltage errors.
V/f
CL-V/f
OLV
CLV
AOLV
This parameter sets the ratio between motor inertia and machine
inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
V/f
CL-V/f
OLV
CLV
AOLV
Selects whether to perform a high frequency injection to detect
motor speed.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
To prevent saturation of the output voltage, set the output voltage
limit. Normally there is no need to configure this setting.
V/f
CL-V/f
OLV
CLV
AOLV
the overvoltage suppression function is working, as a magnification
value. Normally there is no need to configure this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain used for speed estimation. Normally there is no need to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the speed estimation method. Normally there is no need to
change this setting.
0 : Conventional method
1 : A1000 method
V/f
CL-V/f
OLV
CLV
AOLV
Set n8-48 [Pull-In Current (for PM Motors)] to the level of the load
current (q-axis current) to be applied.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
1.0
891
(0.1 - 5.0)
0.80
891
(0.00 - 10.00)
5.0 s
891
(0.0 - 100.0 s)
30%
892
(20 - 200%)
Determined by E5-
892
01
(-200.0 - 0.0%)
Determined by A1-
892
02
(0 - 200%)
1.00 s
892
(0.00 - 10.00 s)
0
893
(0 - 3)
0
893
(0, 1)
200 V Class: 200.0
894
V, 400 V Class:
400.0 V
(200 V Class: 0.0 -
230.0 V, 400 V
Class: 0.0 - 460.0
V)
1.50
894
(0.00 - 10.00)
1.00
894
(0.00 - 20.00)
1
894
(0, 1)
30%
894
(0 - 255%)

Advertisement