10.21 Defaults by Drive Model and Duty Rating ND/HD
No.
Name
*1
Drive
-
Model
Normal /
Heavy
C6-01
Duty
Selection
Drive
o2-04
Model
Hex.
Selection
Motor
E2-11
Rated
(E4-11)
Power
(kW)
Speed
Estimation
b3-06
Current
Level 1
Speed
b3-08
Search
ACR Gain
Direction
b3-26
Determin
ing Level
Energy
b8-03
Saving
Filter Time
Energy
Saving
b8-04
Coefficient
Value
C5-17
Motor
kgm
(C5-37)
Inertia
Carrier
C6-02
Frequency
Selection
Motor
E2-01 (E4-
Rated
01)
Current
E2-02 (E4-
Motor
02)
Rated Slip
Motor No-
E2-03 (E4-
Load
03)
Current
Motor
E2-05 (E4-
Line-to-
05)
Line
Resistance
Motor
E2-06 (E4-
Leakage
06)
Inductance
E2-10 (E4-
Motor Iron
10)
Loss
PM Motor
E5-01
Code
Selection
Momentar
yPower
L2-02
LossRide-
Thru Time
Momenta
ry Power
L2-03
Loss Min
BB Time
534
Unit
-
4031
HD1
ND1
-
0
1
9C
kW
11
15
-
0.5
0.5
-
0.5
0.5
-
1000
1000
s
0.50
0.50
-
140.88
126.26
2
0.053
0.076
-
1
7
A
19.9
26.5
Hz
1.7
1.6
A
5.6
7.6
Ω
0.922
0.55
%
19.6
17.2
W
385
440
-
123D
123D
s
2
2
s
0.9
1
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Default setting
4038
HD1
ND1
HD1
0
1
0
9D
15
18.5
18.5
0.5
0.5
0.5
0.5
0.5
0.5
1000
1000
1000
0.50
0.50
0.50
126.26
115.74
115.74
0.076
0.138
0.138
1
7
1
26.5
32.9
32.9
1.6
1.67
1.67
7.6
7.8
7.8
0.55
0.403
0.403
17.2
20.1
20.1
440
508
508
123E
123E
123F
2
2
2
1
1
1
4044
4060
ND1
HD1
1
0
9E
9F
22
22
0.5
0.5
0.5
0.5
1000
1000
0.50
0.50
103.58
103.58
0.165
0.165
7
1
38.6
38.6
1.7
1.7
9.2
9.2
0.316
0.316
23.5
23.5
586
586
123F
1240
2
2
1
1
ND1
1
30
0.5
0.5
1000
0.50
92.54
0.220
7
52.3
1.8
10.9
0.269
20.7
750
1240
2
1.1

Advertisement