E9-05: Base Voltage
No.
Name
(Hex.)
E9-05
Base Voltage
(11E8)
The value of E9-05 is automatically set to the value input for [Base Voltage] by the EZ Tuning process.
■
E9-06: Motor Rated Current
No.
Name
(Hex.)
E9-06
Motor Rated Current
(11E9)
Note:
Values appear in the following units.
• 2004 to 2042, 4002 to 4023: 0.01 A units
• 2056 to 2415, 4031 to 4675: 0.1 A units
The setting value of E9-06 is the reference value for motor protection. Enter the motor rated current as written on
the motor nameplate. The value of E9-06 is automatically set to the value input for [Motor Rated Current] by the
Auto-Tuning process for motor parameter settings.
■
E9-07: Motor Rated Power (kW)
No.
Name
(Hex.)
E9-07
Motor Rated Power
(kW)
(11EA)
The value of E9-07 is automatically set to the value input for [Motor Rated Power (kW)] by the Auto-Tuning
process for motor parameter settings.
Note:
The value appears in units of 300 kW when the maximum applicable motor output is less than 0.01 kW and appears in units of 300 kW
when over 0.1 kW.
■
E9-08: Motor Pole Count
No.
Name
(Hex.)
E9-08
Motor Pole Count
(11EB)
The value of E9-08 is automatically set to the value input for [Number of Motor Poles] by the Auto-Tuning
process for motor parameter settings.
■
E9-09: Motor Rated Slip
No.
Name
(Hex.)
E9-09
Motor Rated Slip
(11EC)
The setting value of E9-09 is the slip compensation reference value.
Parameter E9-09 is automatically calculated with the setting values of E9-03, E9-04, and E9-08. The value of E9-
09 is automatically set to the value input for [Motor Rated Slip] by the Auto-Tuning process for motor parameter
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Configures the rated voltage of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current in amperes.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated power in 0.01 kW. (1 HP = 0.746 kW)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the motor rated slip.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.6 E: Motor Parameters
Default Setting
(Range)
Determined by E9-01
(200 V Class: 0.0 to
255.0 V,
400 V Class: 0.0 to
510.0 V)
Default Setting
(Range)
Determined by E9-01
and o2-04
(10% to 200% of the
drive rated current)
Default Setting
(Range)
Determined by E9-02
and o2-04
(0.00 - 650.00 kW)
Default Setting
(Range)
4
(2 to 48)
Default Setting
(Range)
0.0 Hz
(0.0 - 20.0 Hz)
709