B: Application; B1: Operation Mode Selection - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.5 b: Application

10.5

b: Application

b1: Operation Mode Selection

No.
Name
(Hex.)
b1-01
Frequency
Reference
(0180)
Selection 1
b1-02
Run Command
Selection 1
(0181)
b1-03
Stopping Method
Selection
(0182)
b1-04
Reverse Operation
Selection
(0183)
b1-05
Operation Below
Minimum Freq
(0184)
b1-06
Digital Input
Reading
(0158)
b1-07
LOCAL/REMOTE
Run Selection
(0186)
400
Description
V/f
CL-V/f
OLV
CLV
AOLV
Selects frequency reference input method.
0 : Keypad or Multi-Speed Selection
1 : Analog Input
2 : MEMOBUS/Modbus communications
3 : Option PCB
4 : Pulse Train Input
V/f
CL-V/f
OLV
CLV
AOLV
Selects the Run command input method.
0 : Keypad
1 : Digital Input
2 : Memobus/Modbus Communications
3 : Option PCB
V/f
CL-V/f
OLV
CLV
AOLV
Selects how the drive stops the motor after removing a Run
command or entering a Stop command.
Note:
The setting range is 0, 1, and 3 when A1-02 = 3, 4, 5, 6, 7, or 8
[Control Method Selection = CLV, AOLV, OLV/PM, AOLV/PM,
CLV/PM, or EZOLV].
0 : Ramp to Stop
1 : Coast to Stop
2 : DC Injection Braking to Stop
3 : Coast to Stop with Timer
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables reverse operation. Used in applications such as
fans or pumps where reverse motor rotation is potentially
problematic.
0 : Reverse Enabled
1 : Reverse Disabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation to perform when the frequency reference falls
below the value set in E1-09 [Minimum Output Frequency].
0 : Operate at frequency reference
1 : Baseblock (motor coasts)
2 : Operate at minimum frequency
3 : Operate at zero speed
V/f
CL-V/f
OLV
CLV
AOLV
Selects if the drive should read the sequence input (FWD/REV,
multi-function input) command once or twice to prevent problems
from noise.
0 : Input status is read once
1 : Input status is read twice
V/f
CL-V/f
OLV
CLV
AOLV
When switching from LOCAL to REMOTE, or between External
reference 1 and External reference 2, the Run command may already
be present at the location to which the source is being switched. In
this case, use parameter b1-07 to determine how the Run command
is treated.
0 : Cycle existing RUN command
1 : Accept existing RUN command
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
1
592
(0 - 4)
1
594
(0 - 3)
0
594
(0 - 3)
0
597
(0, 1)
0
598
(0 - 3)
1
599
(0, 1)
0
599
(0, 1)