Minor
fault code
(Hex.)
0014
CE [MEMOBUS/Modbus Communication Err]
0015
bUS [Option Communication Error]
0016
CALL [Serial Comm Transmission Error]
0017
oL1 [Motor Overload]
0018
oL2 [Drive Overloaded]
001A
EF0 [Option Card External Fault]
001B
rUn [Motor Switch during Run]
001D
CALL [Serial Comm Transmission Error]
001E
UL3 [Undertorque Detection 1]
001F
UL4 [Undertorque Detection 2]
0020
SE [MEMOBUS/Modbus Comm Test Mode Err]
0021
L24v [External 24V Power Supply Depletion]
0022
oH3 [Motor Overheat (PTC)]
0027
FbL [PID Feedback Loss]
0028
FbH [Excessive PID Feedback]
002A
dnE [Drive Disabled]
002B
PGoH [PG Hardware Fault]
0031
E5 [MECHATROLINK Watchdog Timer Err]
AEr [Station Address Setting Error (CC-Link,
0032
CANopen, MECHATROLINK)]
0033
CyC [MECHATROLINK CommCycleSettingErr]

Error Code

MEMOBUS/Modbus Communications Error Code List
The following table lists the MEMOBUS/Modbus communications error codes.
When an error occurs, resolve the cause of the error and restart the communications.
Error Code
Name
(Hex.)
01
Function code error
Register Number
02
Error
03
Bit Count Error
21
Data Setting Error
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Name
Table 5.11 MEMOBUS/Modbus Communications Error Code
A function code other than 03, 08, and 10 (Hex.) was set from PLC.
• No register No. is registered while attempting to access.
• Starting numbers other than 0001 or 0002 (Hex.) were set when broadcasting.
• Read and write data quantities have exceeded the 1 to 16 range. (Command message data
quantity is disabled.)
• In the write mode, the number of bytes in the message is not the number of data × 2.
• Writing control data or parameters made settings go outside the allowable setting range.
• A parameter setting error occurred when writing a parameter.
5.3 MEMOBUS/Modbus Communications
Minor
fault code
(Hex.)
0034
HCA [Current Alarm]
0035
LT-1 [Cooling Fan Maintenance Time]
0036
LT-2 [Capacitor Maintenance Time]
0039
EF1 [External Fault (terminal S1)]
003A
EF2 [External Fault (terminal S2)]
003B
SToF [Safe Disable Signal Input]
003C
STo [Safe Disable Signal Input]
003D
oL5 [Mechanical Weakening Detection 1]
003E
UL5 [Mechanical Weakening Detection 2]
0042
TrPC [IGBT Maintenance Time (90%)]
0043
LT-3 [SoftChargeBypassRelay MainteTime]
0044
LT-4 [IGBT Maintenance Time (50%)]
0045
boL [BrakingTransistor Overload Fault]
0049
dWAL [DriveWorksEZ Fault]
004A
dWA2 [DriveWorksEZ Alarm 2]
004B
dWA3 [DriveWorksEZ Alarm 3]
0081
EP24v [External Power 24V Supply]
0082
LoG [Log Communication Fault]
0085
bAT [Keypad Battery Voltage Low]