B.2 Parameter Table
Para-
meter
b8-02
Energy Saving gain
C2-01
S-curve time at acceleration start
C3-01
Slip compensation gain
C3-02
Slip compensation time constant
C4-01
Torque comp. gain
C4-02
Torque comp. primary delay time
C6-02
Carrier frequency
E1-04
Maximum output frequency
E1-05
Maximum output voltage
E1-06
Base Frequency
E1-07
Middle output frequency
E1-08
Middle output freq. voltage
E1-09
Minimum output frequency
E1-10
Minimum output voltage
E1-11
Middle output frequency 2
E1-12
Middle output freq. voltage 2
E1-13
Base voltage
L1-01
Motor protection selection
L3-20
Accel/Decel rate calculation rate
Decel time at stall prevention during
L3-21
acceleration
<10> Default setting value is dependent on parameter E5-01, Motor Code Selection.
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
Table B.2 E3-01 (Motor 2 Control Mode) Dependent Parameters and Default Values
Para-
meter
E3-04
Maximum output frequency
E3-05
Maximum output voltage
E3-06
Base Frequency
E3-07
Middle output frequency
E3-08
Middle output freq. voltage
E3-09
Minimum output frequency
E3-10
Minimum output voltage
E3-11
Middle output frequency 2
384
Description
<24>
<24>
<24>
<24>
<24>
Description
<24>
<24>
<24>
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Setting Range Resolution
0.0 to 10.0
0.1
0.00 to 10.00
0.01 s
0.0 to 2.5
0.1
0 to 10000
1 msec
0.00 to 2.50
0.01
0 to 10000
1 msec
1 to F
1
40.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 255.0
0.1 V
0 to 4
0.00 to 5.00
0.01
0.00 to 200.00
0.01
Setting Range Resolution
40.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1Hz
0.0 to 400.0
0.1Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
Control Modes (A1-02)
V/f (0)
OLV (2)
0.7
0.20
0.20
0.0
1.0
2000
200
1.00
1.00
200
20
7
7
<12>
<12>
60.0
60.0
200.0
200.0
60.0
60.0
3.0
3.0
16.0
12.0
1.5
0.5
12.0
2.5
0.0
0.0
0.0
0.0
0.0
0.0
-
1
1
1.00
0.30
1.00
1.00
Control Modes (E3-01)
V/f (0)
60.0
200.0
60.0
3.0
16.0
1.5
12.0
0.0
PM (5)
1.00
0.00
100
2
<10>
<10>
<10>
<10>
4
0.65
2.50
OLV (2)
60.0
200.0
60.0
3.0
12.0
0.5
2.5
0.0

Hide quick links: