YASKAWA GA700 Technical Manual page 442

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.9 F: Options
No.
Name
(Hex.)
F7-23
Dynamic Out
through F7-
Assembly 115
27
Param 1 through
10
(03FB -
03FF)
F7-28
through F7-
32
(0370 -
0374)
F7-33
Dynamic In
through F7-
Assembly 165
42
Param 1 through
10
(0375 -
037E)
F7-60
PZD1 Write
(0780)
F7-61
PZD2 Write
(0781)
F7-62
PZD3 Write
(0782)
F7-63
PZD4 Write
(0783)
F7-64
PZD5 Write
(0784)
F7-65
PZD6 Write
(0785)
F7-66
PZD7 Write
(0786)
F7-67
PZD8 Write
(0787)
F7-68
PZD9 Write
(0788)
F7-69
PZD10 Write
(0789)
F7-70
PZD1 Read
(078A)
F7-71
PZD2 Read
(078B)
F7-72
PZD3 Read
(078C)
442
Description
V/f
CL-V/f
OLV
CLV
AOLV
Used for setting the Output Assembly 116. The values received
from the Output Assembly 116 are written to the MEMOBUS/
Modbus address register stored for each parameter. When the
MEMOBUS/Modbus address is 0, the values received from the
Output Assembly 116 are not written to the registers.
V/f
CL-V/f
OLV
CLV
AOLV
Used for setting the input assembly 166. The values sent to the input
assembly 166 are loaded from the MEMOBUS/Modbus address
register stored for each parameter. When the MEMOBUS/Modbus
address is 0, the value sent to the input assembly 166 is not defined,
and so the default register value for the option card is returned.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO output).
PZD1 (PPO output) functions as the STW when F7-60 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO output).
PZD2 (PPO output) functions as the HSW when F7-61 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD3 (PPO output).
When F7-62 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD3 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD4 (PPO output).
When F7-63 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD4 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD5 (PPO output).
When F7-64 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD5 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD6 (PPO output).
When F7-65 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD6 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD7 (PPO output).
When F7-66 = 0, 1, or 2, the write operation to the MEMOBUS
register performed by the PZD7 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD8 (PPO output).
Setting F7-67 = 0, 1, or 2 disables the PZD8 Write.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD9 (PPO output).
When F7-68 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD9 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD10 (PPO output).
When F7-69 = 0, 1, or 2, the write operation to the MEMOBUS/
Modbus register performed by the PZD10 (PPO output) is disabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO Read). PZD1
(PPO input) functions as the ZSW when F7-70 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO Read). PZD2
(PPO input) functions as the HIW when F7-71 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD3 (PPO Read). When
F7-72 = 0, the load operation from the MEMOBUS/Modbus
register performed by the PZD3 (PPO input) is disabled.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0
748
0
748
0
748
0
749
0
749
0
749
0
749
0
749
0
749
0
749
0
750
0
750
0
750
0
750
0
750