YASKAWA GA700 Technical Manual page 69

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

Screw Size
Screw Shape
M4
Slot (-)
M5
Slot (-)
Hex socket cap
M6
(WAF: 5 mm)
Hex socket cap
M8
(WAF: 6 mm)
Hex socket cap
M10
(WAF: 8 mm)
*1
When wiring the drive models 2110 and 4075 or below, select tools correctly based on the wire gauges.
• ≤ 25 mm
2
(AWG 10): TSD-M 3NM
• ≥ 30 mm
2
(AWG 8): Torque wrench that includes a torque measurement range of 4.5 N∙m
*2
Contact Yaskawa or your nearest sales representative for details.
Wiring Procedure (Procedure A)
Remove the keypad and front cover before wiring.
1.
Remove the wiring cover by pulling it forward.
A - Wiring cover
2.
Insert a wire whose ends have been prepared.
Note:
When wiring to terminals +1 and +2, if a jumper connects terminals +1 and +2, first loosen the terminal block screws and
remove the jumper.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
2.13 Wiring Procedure for the Main Circuit Terminal Block
Table 2.17 Recommended Wiring Tools
Adapter
Bit Model
SF-BIT-SL 1,
Bit
0X4,0-70
SF-BIT-SL 1,
Bit
2X6,5-70
Socket
*2
Socket
*2
Socket
*2
Figure 2.38 Remove the Wiring Cover
Figure 2.39 Install the Electrical Wire
Torque Driver
Model
Torque Wrench
Model
(Tightening
Torque)
TSD-M 3NM
-
(1.2 - 3 N∙m)
TSD-M 3NM
*1
(1.2 - 3 N∙m)
*1
-
*2
-
*2
-
*2
Manufacturer
PHOENIX
CONTACT
PHOENIX
CONTACT
*2
*2
*2
2
69

Advertisement

Table of Contents
loading

Table of Contents