YASKAWA GA700 Technical Manual page 452

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.10 H: Terminal Functions
No.
Name
(Hex.)
H2-60
Terminal M1-M2
Function B Select
(1B46)
H2-61
Terminal M1-M2
Logical Operation
(1B47)
H2-62
Terminal M1-M2
Delay Time
(1B48)
H2-63
Terminal M3-M4
Function B Select
(1B49)
H2-64
Terminal M3-M4
Logical Operation
(1B4A)
H2-65
Terminal M3-M4
Delay Time
(1B4B)
H2-66
Terminal M5-M6
Function B Select
(1B4C)
H2-67
Terminal M5-M6
Logical Operation
(1B4D)
H2-68
Terminal M5-M6
Delay Time
(1B4E)
H2-69
Digital Output4
Secondary Func
(1B4F)
H2-70
DigitalOutput4
Logical Operation
(11F9)
H2-71
Digital Output 4
Delay Time
(11FA)
452
Description
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal M1-M2. The logical
calculation results of the terminals assigned to functions by H2-01
[Terminal M1-M2 Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-01
[Terminal M1-M2 Function Select] and H2-60 [Terminal M1-M2
Function B Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical
calculation results from terminal M1-M2.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal M3-M4. The logical
calculation results of the terminals assigned to functions by H2-02
[Terminal M3-M4 Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-02
[Terminal M3-M4 Function Select] and H2-63 [Terminal M3-M4
Function B Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical
calculation results from terminal M3-M4.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal P1-C1. The logical
calculation results of the terminals assigned to functions by H2-03
[Terminal P1-PC Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-03
[Terminal P1-PC Function Select] and H2-66 [Terminal M5-M6
Function B Select].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical
calculation results from terminal P1-C1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the second function for terminal P2-C2. The logical
calculation results of the terminals assigned to functions by H2-04
[Terminal P2-PC Function Select] is output.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the logical operation for the two functions selected by H2-04
[Terminal P2-PC Function Select] and H2-69 [Digital Output4
Secondary Func].
V/f
CL-V/f
OLV
CLV
AOLV
Configures the minimum on time used to output the logical
calculation results from terminal P2-C2.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
F
783
(0 - A7)
0
783
(0 - 8)
0.1 s
783
(0.0 - 25.0 s)
F
784
(0 - A7)
0
784
(0 - 8)
0.1 s
784
(0.0 - 25.0 s)
F
784
(0 - A7)
0
784
(0 - 8)
0.1 s
784
(0.0 - 25.0 s)
F
785
(0 - A7)
0
785
(0 - 8)
0.1 s
785
(0.0 - 25.0 s)