YASKAWA GA700 Technical Manual page 580

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.2 A: Initialization Parameters
User Parameters No.
A2-12
A2-13
A2-14
A2-15
A2-16
7 : Crane (Traveling)
Automatically sets the following parameters for traveling.
No.
A1-02
b1-01
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
H1-05
H1-06
H2-01
H2-02
H3-06
L3-04
L8-05
L8-07
L8-38
L8-41
The drive saves the following parameters as User Parameters.
Table 11.14 Parameters Saved as User Parameters with the Traveling Preset
User Parameters No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
A2-12
580
Parameter No. Saved
Table 11.13 Optimal Settings for Traveling Applications
Name
Control method
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Terminal S5 Function Select
Terminal S6 Function Select
Terminal M1-M2 Function Select
Terminal M3-M4 Function Select
Terminal A3 Function Selection
Decel Stall Prevention Selection
Input Phase Loss Protect Select
Output Phase Loss Protect Select
Carrier Frequency Reduction
High Current Alarm Selection
Parameter No. Saved
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
H2-01
L1-01
L4-01
L6-02
L6-03
b1-01
C1-01
C1-02
C6-02
d1-01
d1-02
d1-03
E2-01
H1-05
H1-06
H2-01
L1-01
Name
Terminal M1-M2 Function Select
Motor Overload Protection Select
Speed Agree Detection Level
Torque Detection Level 1
Torque Detection Time 1
Optimal Value
0: V/f Control
0: Keypad
3.0 s
3.0 s
0: Heavy Duty Rating
2: 5.0 kHz (4.0 kHz for AOLV/PM)
6.00 Hz
30.00 Hz
60.00 Hz
3: Multi-Step Speed Reference 1
4: Multi-Step Speed Reference 2
37: During Frequency Output
37: During Frequency Output
1F: Through Mode
0: Disabled
1: Enabled
1: 1PH Loss Det
1: Enabled below 6 Hz
1: Enabled
Name
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Motor Rated Current
Terminal S5 Function Select
Terminal S6 Function Select
Terminal M1-M2 Function Select
Motor Overload Protection Select

Advertisement

Table of Contents
loading