YASKAWA GA700 Technical Manual page 23

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
12
Option card (connector CN5-C)
• A: No option card
• U: PG-B3 (Complementary Type PG)
• V: PG-X3 (Motor PG Feedback Line Driver Interface)
• W: PG-F3 (encoder interface (for Endat and HIPERFACE))
• Z: PG-RT3 (Motor Feedback Resolver TS2640N321E64 Interface)
13
Keypad
• A: LCD keypad
• B: LCD keypad (humidity-resistant and dust-resistant)
• F: LED keypad
• G: LED keypad (humidity-resistant and dust-resistant)
14
Special applications
A: Standard
The following table lists the rated output current.
Note:
• This table lists the output current values when operating drives at standard specifications.
• Current must be derated in the following circumstances.
–Increasing the carrier frequency
–Installing drives in environments of high ambient temperature
–Installing drives side-by-side
• The normal duty rating (ND) and heavy duty rating (HD) can be configured with parameter C6-01 [Normal / Heavy Duty Selection].
Rated Output Current (Three-Phase AC 200 V)
No.
Max. Applicable Motor
004
006
008
010
012
018
021
030
042
056
070
082
110
138
169
211
257
313
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
Table 1.2 Rated Output Current (Three-Phase AC 200 V)
Heavy Duty Rating (HD)
[C6-01 = 0]
(Default setting)
Rated Output Current
Output
kW
0.4
3.2
0.75
1.1
6.9
1.5
2.2
3
3.7
17.5
5.5
7.5
11
15
18.5
22
30
115
37
145
45
180
55
215
75
283
Normal Duty Rating (ND)
Max. Applicable Motor
Output
A
kW
0.75
5
1.1
1.5
8
2.2
11
3
14
3.7
5.5
25
7.5
33
11
47
15
60
18.5
75
22
88
30
37
45
55
75
90
1.2 Receiving
[C6-01 = 1]
Rated Output Current
A
3.5
6
8
9.6
12.2
17.5
21
30
42
56
70
82
110
138
169
211
257
313
1
23