11.7 F: Options
■
F5-05: Terminal P5-PC Output Selection
No.
Name
(Hex.)
F5-05
Terminal P5-PC
Output Selection
(039D)
■
F5-06: Terminal P6-PC Output Selection
No.
Name
(Hex.)
F5-06
Terminal P6-PC
Output Selection
(039E)
■
F5-07: Terminal M1-M2 Output Selection
No.
Name
(Hex.)
F5-07
Terminal M1-M2
Output Selection
(039F)
■
F5-08: Terminal M3-M4 Output Selection
No.
Name
(Hex.)
F5-08
Terminal M3-M4
Output Selection
(03A0)
■
F5-09: DO-A3 Output Mode Selection
No.
Name
(Hex.)
F5-09
DO-A3 Output Mode
Selection
(03A1)
Refer to
Table 11.39
for more information.
0 : 8 channel individual
1 : Binary code output
2 : 8 channel select(F5-01 to F5-08)
◆
F6, F7: Communication Options
F6 and F7 parameters are used to set the basic communication settings and method of fault detection for the
communication option card. The communication option card parameters include common option card parameters
and communication protocol-specific parameters.
The following table lists the parameters that need to be set for each communication option card.
Refer to the technical manual for each communication option card for more information on installing, wiring, and
configuring the details needed before starting communication.
WARNING! Sudden Movement Hazard. Perform test runs and periodic inspections to ensure that command references are
configured appropriately. Incorrect configuration of the command reference can cause unintended motor rotation, which may
lead to equipment damage or injury.
730
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P5-PC on the DO-A3 card is selected by
the MFDO setting value. This parameter is enabled when F5-09 = 2 [DO-
A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
The function output from terminal P6-PC on the DO-A3 card is selected by
the MFDO setting value. This parameter is enabled when F5-09 = 2 [DO-
A3 Output Mode Selection = 8 channel select(F5-01 to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function output from terminal M3-M2 on the DO-A3 card by the
setting value for the multi-function digital output. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01
to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the function output from terminal M3-M4 on the DO-A3 card by the
setting value for the multi-function digital output. This parameter is enabled
when F5-09 = 2 [DO-A3 Output Mode Selection = 8 channel select(F5-01
to F5-08)].
V/f
CL-V/f
OLV
CLV
AOLV
Selects the output mode of signals output from the DO-A3 card.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
6
(0 - 1A7)
Default Setting
(Range)
37
(0 - 1A7)
Default Setting
(Range)
F
(0 - 1A7)
Default Setting
(Range)
F
(0 - 1A7)
Default Setting
(Range)
0
(0 - 2)