YASKAWA GA700 Technical Manual page 746

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.7 F: Options
F7-08: Subnet Mask 4
No.
Name
(Hex.)
F7-08
Subnet Mask 4
(03EC)
Note:
Be sure to set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-09: Gateway Address 1
No.
Name
(Hex.)
F7-09
Gateway Address 1
(03ED)
Note:
Be sure to set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-10: Gateway Address 2
No.
Name
(Hex.)
F7-10
Gateway Address 2
(03EE)
Note:
Be sure to set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-11: Gateway Address 3
No.
Name
(Hex.)
F7-11
Gateway Address 3
(03EF)
Note:
Be sure to set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-12: Gateway Address 4
No.
Name
(Hex.)
F7-12
Gateway Address 4
(03F0)
Note:
Be sure to set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
F7-13: Address Mode at Startup
No.
Name
(Hex.)
F7-13
Address Mode at
Startup
(03F1)
0 : Static
1 : BOOTP
2 : DHCP
746
V/f
CL-V/f
OLV
CLV
AOLV
Sets the subnet mask of the connected network. Sets the fourth octet.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Gateway address for the connected network. Sets the first octet.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Gateway address for the connected network. Sets the second octet.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Gateway address for the connected network. Sets the third octet.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Gateway address for the connected network. Sets the fourth octet.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the method to set addresses for option cards.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
0
(0 to 255)
Default Setting
(Range)
192
(0 to 255)
Default Setting
(Range)
168
(0 to 255)
Default Setting
(Range)
1
(0 to 255)
Default Setting
(Range)
1
(0 to 255)
Default Setting
(Range)
2
(0 - 2)