Replace A Fan (Procedure B) - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

7.4 Replace a Cooling Fan and Circulation Fan
2.
Properly connect the fan power lines, then place the cable back into the recess of the drive.
A - Drive front surface
3.
Guide the fan finger guard until it clicks back into place while pressing in on the hooks on the left and right
sides of the fan finger guard.
4.
Energize the drive and set o4-03 = 0 [CoolingFan OperationTime Setting = 0 h] to reset it.

Replace a Fan (Procedure B)

WARNING! Electrical Shock Hazard. Do not perform inspections or wiring while the drive is energized. De-energize all devices
before carrying out any wiring or repair operations. Voltage will remain within the capacitors inside the drive even after the
power has been switched off. The Charge LED is extinguished once the DC bus voltage goes below 50 V DC. To prevent
electric shock, always wait for at least the amount of time indicated on the warning labels and confirm that all indicators are
OFF. Then, remove the front cover and terminal cover, measure the input power supply voltage and the DC bus voltage, and
make sure that the voltages have been lowered to safe levels. Failure to comply may result in death or serious injury.
CAUTION! Preventing Burns. Do not touch the heatsink of the drive as it is very hot. To replace cooling fans, de-energize the
drive and wait at least 15 minutes. Make sure the heatsink has sufficiently cooled before proceeding to replace a fan. Touching
the device may result in burns in certain circumstances.
NOTICE: Follow cooling fan replacement instructions. Replace all fans when performing maintenance to help ensure maximum
useful product life. Improper fan replacement could cause damage the drive.
Remove a Fan
1.
Depress the back sides of the fan finger guard tabs forward and pull upward. Remove the fan finger guard
from the top of the drive.
A - Fan finger guard
344
Figure 7.4 Connect Cooling Fan Power Supply Connectors
Figure 7.5 Reattach a Fan Finger Guard
Figure 7.6 Remove a Fan Finger Guard
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual