2.3 Installation Orientation and Spacing

2.3

Installation Orientation and Spacing

Install the drive upright to allow for proper cooling.
Note:
Contact Yaskawa or your nearest sales representative for details on the drive models that can be installed horizontally and their operating
conditions.
A - Upright installation
Single Unit Installation
Install the drive with the clearances specified in
A - At least 50 mm (2 in.)
B - At least 30 mm (1.2 in.) on both
Mounting Multiple Drives Side-by-Side
Drive models 2004xB to 2082xB and 4002xB to 4044xB can take advantage of side-by-side installation.
When installing other drive models, ensure that enough space for single unit installation is placed around each
drive.
When performing side-by-side installation of drives, ensure that enough space is provided for the installation of
the drives with the clearances specified in
Mounting].
Derate the output current to match the ambient temperature.
30
Figure 2.1 Installation Orientation
sides
Figure 2.2 Drive Installation Space (Single Unit)
Figure
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
B - Horizontal installation
Figure 2.2
to guarantee sufficient space for wiring and airflow.
C - At least 120 mm (4.7 in.) above
and below
D - Airflow direction
2.3. Set L8-35 = 1 [Installation Method Selection = Side-by-Side