YASKAWA GA700 Technical Manual page 754

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.8 H: Terminal Functions
H1-05: Terminal S5 Function Select
No.
Name
(Hex.)
H1-05
Terminal S5 Function
Select
(0402)
Note:
When Initialization [A1-03 = 3330] has been performed for a 3-wire sequence, the default setting is 0.
H1-06: Terminal S6 Function Select
No.
Name
(Hex.)
H1-06
Terminal S6 Function
Select
(0403)
Note:
When Initialization [A1-03 = 3330] has been performed for a 3-wire sequence, the default setting is 3.
H1-07: Terminal S7 Function Select
No.
Name
(Hex.)
H1-07
Terminal S7 Function
Select
(0404)
Note:
When Initialization [A1-03 = 3330] has been performed for a 3-wire sequence, the default setting is 4.
H1-08: Terminal S8 Function Select
No.
Name
(Hex.)
H1-08
Terminal S8 Function
Select
(0405)
H1-21: Terminal S1 Function Select 2
No.
Name
(Hex.)
H1-21
Terminal S1 Function
Select 2
(0B70)
Operates the function assigned to H1-01 [Terminal S1 Function Select] and the function assigned to H1-21
simultaneously if the MFDI terminal S1 is turned ON.
When F is assigned as the setting value, the function will be disabled.
H1-22: Terminal S2 Function Select 2
No.
Name
(Hex.)
H1-22
Terminal S2 Function
Select 2
(0B71)
Operates the function assigned to H1-02 [Terminal S2 Function Select] and the function assigned to H1-22
simultaneously if the MFDI terminal S2 is turned ON.
When F is assigned as the setting value, the function will be disabled.
754
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S5.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S6.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S7.
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFDI terminal S8.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the 2nd function for the MFDI terminal S1.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the 2nd function for the MFDI terminal S2.
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default Setting
(Range)
3
(0 - 19F)
Default Setting
(Range)
4
(0 - 19F)
Default Setting
(Range)
6
(0 - 19F)
Default Setting
(Range)
8
(0 - 19F)
Default Setting
(Range)
F
(1 - 19F)
Default Setting
(Range)
F
(1 - 19F)

Advertisement

Table of Contents