YASKAWA GA700 Technical Manual page 390

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

9.9 Peripheral Devices and Options
Name
MECHATROLINK-III
SI-ET3
EtherNet/IP
SI-EN3
ModbusTCP/IP
SI-EM3
LonWorks
SI-W3
PROFINET
SI-EP3
*1
Contact Yaskawa or your nearest sales representative for details.
Option PCB
PG-B3 and PG-X3
PG-F3
and PG-RT3
*2
*2
AO-A3 and DO-A3
AI-A3
, DI-A3
, SI-B3, SI-C3, SI-EM3, SI-EN3, SI-EP3, SI-
*3
*3
ET3, SI-N3, SI-P3, SI-S3, SI-T3, and SI-W3
*1
Use the CN5-C connector when mounting only one PG option card. Use the CN5-C and CN5-B connectors when mounting two PG
option cards.
*2
This cannot be used when using the motor switching function.
*3
When AI-A3 and DI-A3 input statuses are used as monitors, these option cards can be connected to any of CN5-A, CN5-B, and
CN5-C. The AI-A3 input status can be confirmed with U1-21, U1-22, and U1-23. the DI-A3 input status can be confirmed with U1-
17.
390
Model
This option is used to perform the following operations using
the host controller over MECHATROLINK-III
communication.
• Operating and stopping the drive
• Setting and viewing parameters
• Monitoring output frequency, output current, and similar
Note:
Use options with software versions of 6202 or later.
This option is used to perform the following operations using
the host controller over EtherNet/IP communication.
• Operating and stopping the drive
• Setting and viewing parameters
• Monitoring output frequency, output current, and similar
This option is used to perform the following operations using
the host controller over Modbus TCP/IP communication.
• Operating and stopping the drive
• Setting and viewing parameters
• Monitoring output frequency, output current, and similar
Used to perform the following operations using the host
controller over LonWorks communication.
• Operating and stopping the drive
• Setting and viewing parameters
• Monitoring output frequency, output current, and similar
Used to perform the following operations using the host
controller over PROFINET communication.
• Operating and stopping the drive
• Setting and viewing parameters
• Monitoring output frequency, output current, and similar
Table 9.24 Types of Option Cards and Connectors
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Intended Use
Mountable connectors
CN5-C (CN5-B)
CN5-C
CN5-A, B, and C
CN5-A
Document No.
TOBP
C73060088A
SIJPC73060088A
*1
*1
*1
TOBP
C73060089A
SIJPC73060089A
Number of mountable cards
2
*1
1
1
1