Replace A Cooling Fan And Circulation Fan; Number Of Cooling Fans And Circulation Fans Used; Replace A Fan (Procedure A) - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

7.4 Replace a Cooling Fan and Circulation Fan

7.4

Replace a Cooling Fan and Circulation Fan

NOTICE: Follow cooling fan replacement instructions. Replace all fans when performing maintenance to help ensure maximum
useful product life. Improper fan replacement could cause damage the drive.
To replace a cooling fan or circulation fan, contact Yaskawa or your nearest sales representative.
To ensure that the product has the longest possible service life, replace all cooling fans at the same time when
replacing them.

Number of Cooling Fans and Circulation Fans Used

Model
2004 to 2012
2018, 2021
2030, 2042
2056
2070 to 2110
2138 to 2313
2360, 2415
Model
4002 to 4005
4007 to 4012
4018, 4023
4031, 4038
4044 to 4075
4089 to 4296
4371, 4389
4453 to 4675

Replace a Fan (Procedure A)

WARNING! Electrical Shock Hazard. Do not perform inspections or wiring while the drive is energized. De-energize all devices
before carrying out any wiring or repair operations. Voltage will remain within the capacitors inside the drive even after the
power has been switched off. The Charge LED is extinguished once the DC bus voltage goes below 50 V DC. To prevent
electric shock, always wait for at least the amount of time indicated on the warning labels and confirm that all indicators are
OFF. Then, remove the front cover and terminal cover, measure the input power supply voltage and the DC bus voltage, and
make sure that the voltages have been lowered to safe levels. Failure to comply may result in death or serious injury.
CAUTION! Preventing Burns. Do not touch the heatsink of the drive as it is very hot. To replace cooling fans, de-energize the
drive and wait at least 15 minutes. Make sure the heatsink has sufficiently cooled before proceeding to replace a fan. Touching
the device may result in burns in certain circumstances.
NOTICE: Follow cooling fan replacement instructions. Replace all fans when performing maintenance to help ensure maximum
useful product life. Improper fan replacement could cause damage the drive.
342
Table 7.11 Cooling Fans and Circulation Fans (Three-Phase 200 V)
Cooling fan
-
1
2
2
Table 7.12 Cooling Fans and Circulation Fans (Three-Phase 400 V)
Cooling fan
Circulation Fans
-
1
2
2
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Circulation Fans
-
-
-
-
Preparing
Circuit Board Cooling
Fans
-
-
-
-
-
-
-
-
Preparing
Replacement Procedure
-
Procedure A
Procedure B
Procedure C
Replacement
Procedure
-
Procedure A
Procedure B
Procedure C

Advertisement

Table of Contents
loading

Table of Contents