L8: Hardware Protection - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
L7-16
Torque Limit
Process at Start
(044D)
L7-35
DeratingTrqLim
ForLowFreq&Re
(1B57)
gratn
L7-36
Ope Freq band for
deratingTrqLim
(1B58)

L8: Hardware Protection

No.
Name
(Hex.)
L8-01
Internal DB
Resistor Protect Sel Enabled braking resistor protection of the when using an optional
(04AD)
L8-02
Overheat Alarm
Level
(04AE)
L8-03
Overheat Pre-
Alarm Ope
(04AF)
Selection
L8-05
Input Phase Loss
Protect Select
(04B1)
L8-07
Output Phase Loss
Protect Select
(04B3)
L8-09
Output Ground
Fault DetectSelect Enables or disables ground fault protection.
(04B5)
L8-10
Heatsink Cooling
Fan Ope Select
(04B6)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Assigns a time filter to allow the torque limit to build at start.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit used during low-speed regeneration. Normally
there is no need to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency width at which L7-35 [Derating Trq Lim For
Low Freq & Regeneration] operates.
Description
V/f
CL-V/f
OLV
CLV
AOLV
heatsink mounted braking resistor (ERF type, 3% ED).
0 : Not Provided
1 : Provided
V/f
CL-V/f
OLV
CLV
AOLV
Sets the oH detection level in temperature.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation of drives when an oH alarm is detected.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast-Stop
3 : Alarm Only
4 : Run@L8-19 Rate
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables input phase loss detection.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the output phase loss detection. Output phase
loss detection is triggered when the output current falls below 5% of
the drive rated current.
Note:
Output phase loss detection can mistakenly be triggered in the
following situations. Disable output phase loss protection.
• The motor rated current is very small compared to the drive
rating.
• Operates PM motors with light loads.
0 : Disabled
1 : 1PH Loss Det
2 : 2/3PH Loss Det
V/f
CL-V/f
OLV
CLV
AOLV
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Selects the heatsink cooling fan operation.
0 : Dur Run (OffDly)
1 : Always On
2 : Fan ON in heating of Drive
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.11 L: Protection Function
Default
Ref.
(Range)
1
864
(0, 1)
50.00%
864
(0.00 - 200.00%)
6.00 Hz
864
(0.00 - 30.00 Hz)
Default
Ref.
(Range)
0
865
(0, 1)
Determined by o2-
865
04 and C6-01
(50 - 150 °C)
3
865
(0 - 4)
0
866
(0, 1)
0
866
(0 - 2)
Determined by o2-
867
04
(0, 1)
0
867
(0 - 2)
10
473

Advertisement