Dead Zone Generator - Samsung S5PC110 Manual

Risc microprocessor
Table of Contents

Advertisement

S5PC110_UM

1.3.8 DEAD ZONE GENERATOR

This feature inserts the time gap between a turn-off and turn-on of two different switching devices. This time gap
prohibits the two switching device turning on simultaneously even for a very short time.
TOUT_0 specifies the PWM output. nTOUT_0 specifies the inversion of the TOUT_0. If the dead-zone is enabled,
the output wave-form of TOUT_0 and nTOUT_0 is TOUT_0_DZ and nTOUT_0_DZ. TOUT0_DZ and
nTOUT_0_DZ cannot be turned on simultaneously by the dead zone interval. For functional correctness, the dead
zone length must be set smaller than compare counter value.
TOUT0
nTOUT0
DEADZONE
INTERVAL
TOUT0_DZ
nTOUT0_DZ
Figure 1-8
Waveform when a Deadzone Feature is Enabled
1 PULSE WIDTH MODULATION TIMER
1-11