2.3.2 DATA TRANSFER FORMAT

Every byte placed on the SDA line should be eight bits in length. There is no limit to transmit bytes per transfer.
The first byte following a Start condition should have the address field. If the I
master transmits the address field. Each byte should be followed by an acknowledgement (ACK) bit. The MSB bit
of the serial data and addresses are sent first.
SDA
MSB
1
SCL
S
Write Mode Format with 7-bit Addresses
S Slave Address 7bits R/W A
(Write)
Read Mode Format with 7-bit Addresses
S Slave Address 7 bits R/W A
(Read)
NOTES:
1.
S: Start, rS: Repeat Start, P: Stop, A: Acknowledge
2.
: From Master to Slave,
Figure 2-3
Acknowledgement
Signal from Receiver
2
7
8
Byte Complete, Interrupt
within Receiver
Figure 2-4
DATA(1Byte)
"0"
Data Transferred
(Data + Acknowledge)
DATA
"1"
Data Transferred
(Data + Acknowledge)
: From Slave to Master
2
I
C-Bus Interface Data Format
9
1
ACK
Data Transfer on the I
2 IIC-BUS INTERFACE
2
C-bus is operating in Master mode,
A
P
A
P
Acknowledgement
Signal from Receiver
2
9
Clock Line Held Low by
receiver and/or transmitter
2
C-Bus